18 / 24 page ![]() 18 LTC1325 APPLICATIONS INFORMATION between the VBAT and Sense pins and the internal divider should be set to divide-by-1. The minimum VDD supply must be greater than the end-of-charge voltage VEC times the number of cells (n) in the battery plus drops across the on-resistance of the PFET, inductor (VL), battery internal resistance RINT and sense resistor RSENSE. Minimum VDD should be the greater voltage of the results from these two equations: Min VDD =ICHRG[RDS(ON)(P1) + RSENSE + n(RINT)] + n(VEC) + VL or, Min VDD = n(VEC) + 1.8V Assuming VEC = 1.6V, the LTC1325 will charge up to 8 cells with a 16V supply. For a higher number of cells, an external level shifter and regulator are needed. In some applications, there are other circuits attached to the charging supply. When the charging supply (VDC) is powered down or removed, the battery may supply current to these circuits through the PFET body diode. To prevent this, a blocking diode can be added in series with VDC as shown in the circuit in the Typical Application section. 3. Inductor L: To minimize losses, the inductor should have low winding resistance. It should be able to handle expected peak charging currents without satu- ration. If the inductor saturates, the charging current is limited only by the total PFET RDS(ON), inductor winding resistance, RSENSE and VDD source resis- tance. This fault current may be high enough to damage the battery or cause the maximum power ratings of the PFET, inductor or RSENSE to be ex- ceeded. 4. Catch Diode D1: The catch diode should have a low forward drop and fast reverse recovery time to mini- mize power dissipation. Total power loss is given by: PdD1 = VF(IF) + (VR)(f)(tRR)(IF′) The LTC1325 has five duty ratio and four VDAC settings giving 20 possible charge rates (for a given value of RSENSE) as shown in the following table. For any combination of VDAC and duty ratio, the average charging current is given by: AVG ICHRG = VDAC(Duty Ratio)/RSENSE NORMALIZED DUTY RATIO VDAC 1 1/2 1/4 1/8 1/16 1(VR1 = 1, VR0 = 1) 1 1/2 1/4 1/8 1/16 1/3(VR1 = 1, VR0 = 0) 1/3 1/6 1/12 1/24 1/48 1/5(VR1 = 0, VR0 = 1) 1/5 1/10 l/20 1/40 1/80 1/10(VR1 = 0, VR0 = 0) 1/10 1/20 1/40 1/80 1/160 Note that the table entries give relative charge rates assuming that the VR1 = 1, VR0 = 1, duty ratio = 1 entry is equivalent to a 1C charge rate. Therefore, the charge rate (in C-units) for other VR1, VR0, and duty ratio settings may be read directly from the table. In gen- eral, the VR1 = 1, VR0 = 1, duty ratio = 1 entry can be equivalent to any charge rate, say k times 1C. Then all entries in the table should be multiplied by k. In general, VDAC and duty ratio settings are changed by the microprocessor to charge batteries of different capacities or to alter charge rates when charging the same battery in several stages. For best accuracy, VR1 and VR0 should be set to 1 where possible. The power dissipation of the sense resistor varies between charge, discharge and gas gauge modes and should be calculated for all three modes. Typically, dissipation is higher in discharge and gas gauge modes since batteries can deliver higher currents than they can be charged with. In gas gauge mode, the load current supplied by the battery should not exceed 450mV/RSENSE for the gas gauge to remain linear in response. RSENSE should be low enough to ensure that ILOAD(RSENSE) does not fall below ground by more than 1 diode drop. 2. VDD Supply: VDD should be at least 1.8V above the maximum battery voltage to prevent a BATP = 0 error when the LTC1325 is in charge or discharge mode. If this requirement cannot be met in a specific applica- tion, an external battery divider should be connected |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |