| Electronic Components Datasheet Search |
|
LF3310 Datasheet(PDF) 13 Page - LOGIC Devices Incorporated |
|
|
|||||||||||||||||||||||||||||
LF3310 Datasheet(HTML) 13 Page - LOGIC Devices Incorporated |
|
13 / 21 page ![]() DEVICES INCORPORATED Video Imaging Products 13 LF3310 Horizontal / Vertical Digital Image Filter 11/08/2001-LDS.3310-H ADDR1 COEF0 COEF1 COEFFICIENT SET 1 CLK HLD/VLD HCF/VCF11-0 W1 W1: Coefficient Set 1 written to coefficient banks during this clock cycle. HPAUSE/VPAUSE COEF7 ADDR1 DATA1 ADDR2 CONFIGURATION REGISTER CLK W2 W1: Configuration Register loaded with new data on this rising clock edge. HPAUSE/VPAUSE DATA1 SELECT REGISTER W1 W2: Select Register loaded with new data on this rising clock edge. HLD/VLD HCF/VCF11-0 FIGURE 15. CONFIGURATION AND SELECT REGISTER LOADING SEQUENCE WITH HPAUSE AND VPAUSE IMPLEMENTATION FIGURE 14. COEFFICIENT BANK LOADING SEQUENCE WITH HPAUSE AND VPAUSE IMPLEMENTATION HLD goes LOW, the Horizontal LF InterfaceTM is enabled for data input. The first value fed into the interface on HCF11-0 is an address which determines what the interface is going to load. The three most significant bits (HCF11-9) determine if the LF InterfaceTM will load coefficient banks or Configuration/Control Registers (see Table 8). The nine least signifi- cant bits (HCF8-0) are the address for whatever is to be loaded (see Tables 9-14). For example, to load address 15 of the horizontal coefficient banks, the first data value into the LF InterfaceTM should be 00FH. To load horizontal limit register 10, the first data value should be C0AH. The first address value should be loaded into the interface on the same clock cycle that latches the HIGH to LOW transition of HLD (see Figures 12 and 13). The next value(s) loaded into the interface are the data value(s) which will be stored in the bank or register defined by the address value. When loading coefficient banks, the inter- face will expect eight values to be loaded into the device after the address value. The eight values are coefficients 0 through 7. When loading select or Configuration Registers, the interface will expect one value after the address value. When loading round registers, the interface will expect four values after the address value. When loading limit registers, the interface will expect two values after the address value. Figures 12 and 13 show the data loading sequences for the coefficient banks and Configuration/Control Registers. Both HPAUSE and VPAUSE allow the user to effectively slow the rate of data loading through the LF InterfaceTM. When HPAUSE is HIGH, the LF InterfaceTM affecting the data used for the Horizontal Filter is held until HPAUSE is returned to a LOW. When VPAUSE is HIGH, the LF InterfaceTM affecting the data used for the Vertical Filter is held until VPAUSE is returned to a LOW. Figures 14 through 17 display the effects of both HPAUSE and VPAUSE while loading coefficient and control data. Table 15 shows an example of loading data into the coefficient banks. The following data values are written into address 10 of coefficient banks 0 through 7: 210H, 543H, C76H, 9E3H, 701H, 832H, F20H, 143H. Table 16 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |