5 / 28 page ![]() 2002 Microchip Technology Inc. DS21449C-page 5 TC649 3.0 DETAILED DESCRIPTION 3.1 PWM The PWM circuit consists of a ramp generator and threshold detector. The frequency of the PWM is determined by the value of the capacitor connected to the CF input. A frequency of 30 Hz is recommended for most applications (CF = 1 µF). The PWM is also the time base for the Start-up Timer (see Section 3.3, “Start-up Timer”). The PWM voltage control range is 1.25V to 2.65V (typical) for 0% to 100% output duty cycle. 3.2 VOUT Output The VOUT pin is designed to drive a low cost transistor or MOSFET as the low side power switching element in the system. Various examples of driver circuits will be shown throughout the datasheet. This output has asymmetric complementary drive and is optimized for driving NPN transistors or N-channel MOSFETs. Since the system relies on PWM rather than linear control, the power dissipation in the power switch is kept to a minimum. Generally, very small devices (TO-92 or SOT packages) will suffice. 3.3 Start-Up Timer To ensure reliable fan start-up, the Start-up Timer turns the VOUT output on for 32 cycles of the PWM whenever the fan is started from the off state. This occurs at power-up and when coming out of shutdown or auto- shutdown mode. If the PWM frequency is 30 Hz (CF = 1 µF) the resulting start-up time will be approximately one second. If a fan fault is detected (see Section 3.5, FAULT Output), the Diagnostic Timer is triggered once, followed by the Start-up Timer. If the fault persists, the device is shut down (see Section 3.5, FAULT Output). 3.4 SENSE Input (FanSense™ Technology) The SENSE input (Pin 5) is connected to a low value current sensing resistor in the ground return leg of the fan circuit. During normal fan operation, commutation occurs as each pole of the fan is energized. This causes brief interruptions in the fan current, seen as pulses across the sense resistor. If the device is not in shutdown or auto-shutdown mode, and pulses are not appearing at the SENSE input, a fault exists. The short, rapid change in fan current (high dl/dt) causes a corresponding dV/dt across the sense resistor, RSENSE. The waveform on RSENSE is differentiated and converted to a logic-level pulse-train by CSENSE and the internal signal processing circuitry. The presence and frequency of this pulse-train is a direct indication of fan operation. See Section 5.0, “Typical Applications”, for more details. 3.5 FAULT Output Pulses appearing at SENSE due to the PWM turning on are blanked, and the remaining pulses are filtered by a missing pulse detector. If consecutive pulses are not detected for thirty-two PWM cycles ( ≅1Sec if CF = 1 µF), the Diagnostic Timer is activated, and VOUT is driven high continuously for three PWM cycles ( ≅100 msec if CF = 1 µF). If a pulse is not detected within this window, the Start-up Timer is triggered (see Section 3.3, “Start-up Timer”). This should clear a tran- sient fault condition. If the missing pulse detector times out again, the PWM is stopped and FAULT goes low. When FAULT is activated due to this condition, the device is latched in shutdown mode and will remain off indefinitely. The TC649 is thus prevented from attempting to drive a fan under catastrophic fault conditions. One of two things will restore operation: Cycling power off and then on again; or pulling VIN below VSHDN and releasing it to a level above VREL. When one of these two conditions is satisfied, the normal start-up cycle is triggered and operation will resume, provided the fault has been cleared. 3.6 Auto-Shutdown Mode If the voltage on VIN becomes less than the voltage on VAS, the fan is automatically shut off (auto-shutdown mode). The TC649 exits auto-shutdown mode when the voltage on VIN becomes higher than the voltage on VAS by VHAS (the auto-shutdown hysteresis voltage, see Figure 3-1). The Start-up Timer is triggered and normal operation is resumed upon exiting auto-shut- down mode. The FAULT output is unconditionally inactive in auto-shutdown mode. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |