| Electronic Components Datasheet Search |
|
CF5760 Datasheet(PDF) 5 Page - Nippon Precision Circuits Inc |
|
|
|||||||||||||||||||||||||||||
CF5760 Datasheet(HTML) 5 Page - Nippon Precision Circuits Inc |
|
5 / 7 page ![]() CF5760 series SEIKO NPC CORPORATION —5 Reset Function (optional seconds control function) When AI/R goes active level for a reset, the motor output stops. When the reset is released, the first motor out- put pulse occurs on the output pin opposite to that which had the last output pulse immediately before the reset. Alarm Output Alarm output waveform F Output Function The AON pin may be replaced by the F pin which is used to output a 32kHz signal (unaffected by the reset function). *1: Opposite phase to AO. fPW = alarm fundamental frequency fCY = alarm modulation frequency O1 (Active High) O2 (Active High) tPW tPW tCY tCY AI/R (Active Low) tCY +0 −125msec tON AO (Active High) AI/R (Active High) AON (Active Low) fPW(Hz ) fCY (Hz ) tON *1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|