  LM4140ACM-1.2/NOPB Datasheet HTML 1Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 2Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 3Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 4Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 5Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 6Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 7Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 8Page - Texas Instruments LM4140ACM-1.2/NOPB Datasheet HTML 9Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 23 page
background image
LM4140
www.ti.com
SNVS053E – JUNE 2000 – REVISED APRIL 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1) (2)
Maximum Voltage on any Input pin
−0.3V to 5.6V
Output Short-Circuit Duration
Indefinite
Power Dissipation (TA = 25°C)
(3)
345mW
ESD Susceptibility (4)
Human Body Model
2 kV
Machine Model
200V
Lead Temperature:
Soldering, (10 sec.)
+260°C
(1)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but do not ensure specific performance limits. For ensured specifications and test
conditions, see Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance
characteristics may degrade when the device is not operated under the listed test conditions.
(2)
If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and
specifications.
(3)
Without PCB copper enhancements. The maximum power dissipation must be de-rated at elevated temperatures and is limited by TJMAX
(maximum junction temperature),
θJ-A (junction to ambient thermal resistance) and TA (ambient temperature). The maximum power
dissipation at any temperature is: PDissMAX = (TJMAX − TA)/θJ-A up to the value listed in the Absolute Maximum Ratings. The θJ-A for the
SO-8 package is 160°C/W.
(4)
The human body model is a 100 pF capacitor discharged through a 1.5 k
Ω resistor into each pin. The machine model is a 200 pF
capacitor discharged directly into each pin.
Operating Range
(1)
Storage Temperature Range
−65°C to +150°C
Ambient Temperature Range
0°C to 70°C
Junction Temperature Range
0°C to 80°C
(1)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but do not ensure specific performance limits. For ensured specifications and test
conditions, see Electrical Characteristics. The ensured specifications apply only for the test conditions listed. Some performance
characteristics may degrade when the device is not operated under the listed test conditions.
LM4140
Electrical Charateristics
Unless otherwise specified, VIN = 3.0V for the LM4140-1.024 and LM4140-1.250, VIN = 5.0V for all other voltage options, VEN
= VIN. COUT = 1μF
(1), I
LOAD = 1mA, TA = TJ = 25°C. Limits with standard typeface are for TA = 25°C, and limits in boldface
type apply over 0°C to 70°C temperature range.
Min
Typ
Max
Symbol
Parameter
Conditions
Units
(2)
(3)
(2)
Output Voltage Initial Accuracy
(4)
LM4140B-1.024
LM4140B-1.250
±0.1
LM4140B-2.048
LM4140B-2.500
VREF
%
LM4140B-4.096
LM4140C-1.024
LM4140C-1.250
LM4140C-2.048
±0.1
LM4140C-2.500
LM4140C-4.096
(1)
For proper operation, a 1
μF capacitor is required between the output pin and the GND pin of the device. (See Application Hints for
details)
(2)
Limits are 100% production tested at 25°C. Limits over the operating temperature range are ensured through correlation using Statistical
Quality Control (SQC) methods. The limits are used to calculate TI's Average Outgoing Quality Level (AOQL).
(3)
Typical numbers are at 25°C and represent the most likely parametric norm.
(4)
High temperature and mechanical stress associated with PCB assembly can have significant impact on the initial accuracy of the
LM4140 and may create significant shifts in VREF. See Application Hints section regarding accuracy and PCB layout consideration.
Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
3
Product Folder Links: LM4140



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com