| Electronic Components Datasheet Search |
|
DRV8313PWPR Datasheet(PDF) 13 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
DRV8313PWPR Datasheet(HTML) 13 Page - Texas Instruments |
|
13 / 37 page ![]() 13 DRV8313 www.ti.com SLVSBA5C – OCTOBER 2012 – REVISED NOVEMBER 2015 Product Folder Links: DRV8313 Submit Documentation Feedback Copyright © 2012–2015, Texas Instruments Incorporated 7.3.5 Protection Circuits The DRV8313 has full protection against undervoltage, overcurrent, and overtemperature events. 7.3.5.1 Undervoltage Lockout (UVLO) If at any time the voltage on the VM pin falls below the undervoltage threshold voltage (VUVLO), all FETs in the H- bridge will be disabled, the charge pump will be disabled, the internal logic is reset, and the nFAULT pin will be driven low. Operation will resume when VM rises above the UVLO threshold. The nFAULT pin will be released after operation has resumed. 7.3.5.2 Thermal Shutdown (TSD) If the die temperature exceeds safe limits, all FETs in the H-bridge will be disabled and the nFAULT pin will be driven low. Once the die temperature has fallen to a safe level operation will automatically resume. The nFAULT pin will be released after operation has resumed. 7.3.5.3 Overcurrent Protection (OCP) An analog current limit circuit on each FET limits the current through the FET by removing the gate drive. If this analog current limit persists for longer than tOCP, the device disables the channel experiencing the overcurrent and drives the nFAULT pin low. The driver remains off until either assertion of nRESET or the cycling of VM power. Overcurrent conditions on both high- and low-side devices, that is, a short to ground, supply, or across the motor winding, all result in an overcurrent shutdown. Table 2. Fault Condition Summary FAULT CONDITION ERROR REPORT H-BRIDGE CHARGE PUMP V3P3 RECOVERY VM undervoltage (UVLO) VM < VUVLO (max 8 V) nFAULT Disabled Disabled Operating VM > VUVLO (max 8 V) Thermal Shutdown (TSD) TJ > TTSD (min 150°C) nFAULT Disabled Operating Operating TJ < TTSD - THYS (THYS typ 35°C) Overcurrent (OCP) IOUT > IOCP (min 3 A) nFAULT Disabled Operating Operating nRESET |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |