Back Button SP6120HVCY Datasheet HTML 11Page - Sipex Corporation SP6120HVCY Datasheet HTML 12Page - Sipex Corporation SP6120HVCY Datasheet HTML 13Page - Sipex Corporation SP6120HVCY Datasheet HTML 14Page - Sipex Corporation SP6120HVCY Datasheet HTML 15Page - Sipex Corporation SP6120HVCY Datasheet HTML 16Page - Sipex Corporation SP6120HVCY Datasheet HTML 17Page - Sipex Corporation SP6120HVCY Datasheet HTML 18Page - Sipex Corporation SP6120HVCY Datasheet HTML 19Page - Sipex Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 15 / 22 page
background image
15
Date: 5/25/04
SP6120HV Low Voltage, Synchronous Buck Controller
© Copyright 2004 Sipex Corporation
large enough so that the output voltage is held up
while the inductor current ramps up or down to
the value corresponding to the new load current.
Additionally, the ESR in the output capacitor
causes a step in the output voltage equal to the
ESR value multiplied by the change in load
current. Because of the fast transient response
and inherent 100% and 0% duty cycle capabil-
ity provided by the SP6120HV when exposed to
output load transient, the output capacitor is
typically chosen for ESR, not for capacitance
value.
The output capacitor’s ESR, combined with the
inductor ripple current, is typically the main
contributor to output voltage ripple. The maxi-
mum allowable ESR required to maintain a
specified output voltage ripple can be calculated
by:
PP
OUT
ESR
I
V
R
∆
≤
where:
∆VOUT = peak to peak output voltage ripple
IPP = peak to peak inductor ripple current
The total output ripple is a combination of the
ESR and the output capacitance value and can
be calculated as follows:
∆VOUT =
(IPP(1–D))
2
+ (IPPRESR)2
COUTFS
where:
FS = switching frequency
D = duty cycle
COUT = output capacitance value
Recommended capacitors that can be used ef-
fectively in SP6120HV applications are: low-
ESR aluminum electrolytic capacitors, OS-CON
capacitors that provide a very high performance/
size ratio for electrolytic capacitors and low-
ESR tantalum capacitors. AVX TPS series and
Kemet T510 surface mount capacitors are popu-
lar tantalum capacitors that work well in
SP6120HV applications. POSCAP from Sanyo
is a solid electrolytic chip capacitor that has low
ESR and high capacitance. For the same ESR
value, POSCAP has lower profile compared
with tantalum capacitor.
Input Capacitor Selection
The input capacitor should be selected for ripple
current rating, capacitance and voltage rating.
The input capacitor must meet the ripple current
requirement imposed by the switching current.
In continuous conduction mode, the source cur-
rent of the high-side MOSFET is approximately
a square wave of duty cycle VOUT/VIN. Most of
this current is supplied by the input bypass
capacitors. The RMS value of input capacitor
current is determined at the maximum output
current and under the assumption that the peak
to peak inductor ripple current is low, it is given
by:
I
CIN(rms) = IOUT(max)
√D(1 - D)
The worse case occurs when the duty cycle D is
50% and gives an RMS current value equal to
IOUT /2. Select input capacitors with adequate
ripple current rating to ensure reliable opera-
tion.
The power dissipated in the input capacitor is:
)
(
2
)
(
CIN
ESR
rms
CIN
CIN
R
I
P
=
This can become a significant part of power
losses in a converter and hurt the overall energy
transfer efficiency.
The input voltage ripple primarily depends on
the input capacitor ESR and capacitance. Ignor-
ing the inductor ripple current, the input voltage
ripple can be determined by:
2
)
(
)
(
(max)
)
(
IN
IN
S
OUT
IN
OUT
MAX
OUT
CIN
ESR
out
IN
V
C
F
V
V
V
I
R
I
V
−
+
=
∆
The capacitor type suitable for the output ca-
pacitors can also be used for the input capaci-
tors. However, exercise extra caution when tan-
talum capacitors are considered. Tantalum ca-
pacitors are known for catastrophic failure when
exposed to surge current, and input capacitors



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com