47 / 92 page ![]() HighThreshold LowThreshold Hysteresis Input Hysteresis OverHighAlarm BelowLowAlarm AMC7812B www.ti.com SBAS625A – SEPTEMBER 2013 – REVISED SEPTEMBER 2013 Hysteresis The device continuously monitors the analog input channels and temperatures. If any alarms are out of range and the alarm is enabled, the alarm bit is set ('1'). However, the alarm condition is cleared only when the conversion result returns to a value of at least hys below the value of the high threshold register, or hys above the value of low threshold register. The hysteresis registers store the value for each analog input (CH0, CH1, CH2, and CH3) and temperature (D1, D2, and LT). hys is the value of hysteresis that is programmable: 0 LSB to 127 LSB for analog inputs, and 0°C to +31°C for temperatures. For the THERM-ALR bit, the hysteresis is fixed at 8°C. The hysteresis behavior is shown in Figure 98. Figure 98. Hysteresis False-Alarm Protection As noted previously, the device continuously monitors all analog inputs and temperatures in normal operation. When any input is out of the specified range in N consecutive conversions, the corresponding alarm bit is set ('1'). If the input returns to the normal range before N consecutive times, the alarm bit remains clear ('0'). This design avoids false alarms. The number N is programmable by the CH-FALR-CT-[2:0] bits in AMC configuration register 1 for analog input CHn as shown in Table 6, or by the TEMP-FALR-CT-[1:0] bits for temperature monitors as shown in Table 7. Table 6. Consecutive Sample Number for False Alarm Protection for CHn N CONSECUTIVE SAMPLES CH-FALR-CT-2 CH-FALR-CT-1 CH-FALR-CT-0 BEFORE ALARM IS SET 0 0 0 1 0 0 1 4 0 1 0 8 0 1 1 16 (default) 1 0 0 32 1 0 1 64 1 1 0 128 1 1 1 256 Table 7. Consecutive Sample Number for False Alarm Protection for Temperature Channels TEMP-FALR-CT-1 TEMP-FALR-CT-0 N CONSECUTIVE SAMPLES BEFORE ALARM IS SET 0 0 1 0 1 2 1 0 4 (default) 1 1 8 Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 47 Product Folder Links: AMC7812B |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |