23 / 38 page ![]() SCAN25100 www.ti.com SNLS223C – SEPTEMBER 2006 – REVISED APRIL 2013 MDIO Serial Control Interface The MDIO serial control interface allows communication between a station management controller and SCAN25100 devices. MDIO and MDC pins are 3.3V LVTTL compliant, not 1.2V compatiable. It is software compatible with the station management bus defined in IEEE 802.3ae-2002. The serial control interface consists of two pins, the data clock MDC and bidirectional data MDIO. MDC has a maximum clock rate of 2.5 MHz and no minimum limit. The MDIO is bidirectional and can be shared by up to 32 physical devices. The MDIO pin requires a pull-up resistor which, during IDLE and turnaround, will pull MDIO high. The parallel equivalence of the MDIO when shared with other devices should not be less than 1.5 k Ω. Note that with many devices in parallel, the internal pull-up resistors add in parallel. Signal quality on the net should provide incident wave switching. It may be desirable to control the edge rate of MDC and MDIO from the station management controller to optimize signal quality depending upon the trace net and any resulting stub lengths. In order to initialize the MDIO interface, the station management sends a sequence of 32 contiguous logic ones on MDIO with MDC clocking. This preamble may be generated either by driving MDIO high for 32 consecutive MDC clock cycles, or by simply allowing the MDIO pull-up resistor to pull the MDIO high for 32 MDC clock cycles. A preamble is required for every operation (64-bit frames, do not suppress preambles). MDC is an a periodic signal. Its high or low duration is 160 ns minimum and has no maximum limit. Its period is 400 ns minimum. MDC is not required to maintain a constant phase relationship with TXCLK, SYSCLK, and REFCLK. The following table shows the management frame structure in according to IEEE 802.3ae. Table 15. 802.3ae MDIO Bus Protocol Mgmt Bus Protocol <Preamble><Start><OpCode><PHY addr><dev addr><turnaround><data><idle> Address <1…1><00><00><PPPPP><EEEEE><10><AAAA AAAA AAAA AAAA><idle> Write <1…1><00><01><PPPPP><EEEEE><10><DDDD DDDD DDDD DDDD><idle> Read <1…1><00><11><PPPPP><EEEEE><Z0><DDDD DDDD DDDD DDDD><idle> Read-Increment-Address <1…1><00><10><PPPPP><EEEEE><Z0><DDDD DDDD DDDD DDDD><idle> <1…1> is a sequence of 32 contiguous ones and is used as preamble for synchronization purposes. <PPPPP> is the PHY address of the device, defined by the logic states of ADD[4:0]. The MSB bit is the first bit transmitted or received. The PHY address is read at power-up or after a RESET event. <EEEEE> is the device (register) address. The MSB bit is the first bit transmitted or received. <AAAA AAAA AAAA AAAA> is the 16-bit address field of the register to be accessed. The first bit transmitted or received is bit 15. <DDDD DDDD DDDD DDDD> is the 16-bit data field. It is the data to be written into the SCAN25100 when performing a Write operation. During the Read or Read-Increment-Address operation, it is the read-back data from the SCAN25100. The first bit transmitted or received is bit 15. MDIO OPERATION The MDIO interface is active when the SCAN25100 is powered up, REFCLK is present, and the SCAN25100 not being reset through the RESETB pin. The MDIO bus returns the following data: • Correct PHY ADD, Correct DEV ADD — expected content • Incorrect PHY ADD, Correct DEV ADD — FFFF’h • Correct PHY ADD, Incorrect DEV ADD — 0000’h • RESETB = Low — FFFF’h The Start code is indicated by a <01> pattern. This assures the MDIO line transitions from the default idle line state. Turnaround is defined as an idle bit time inserted between the Register Address field and the Data field. To avoid contention during a read transaction, no device shall actively drive the MDIO signal during the first bit of the turnaround. The addressed SCAN25100 drives the MDIO with a zero for the second bit if the turnaround and follows this with the required data. Figure 8 shows the timing relationship between MDC and MDIO as driven/received by the Station and the SCAN25100 for a typical read register access. Copyright © 2006–2013, Texas Instruments Incorporated Submit Documentation Feedback 23 Product Folder Links: SCAN25100 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |