| Electronic Components Datasheet Search |
|
SCAN25100TYAX/NOPB Datasheet(PDF) 12 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SCAN25100TYAX/NOPB Datasheet(HTML) 12 Page - Texas Instruments |
|
12 / 38 page ![]() Power Up Synchronize Read/Write Data after a link resynchronization event (reset, power down, loss of lock, comma (re)align- ment, etc.) This state flushes and resets internal FIFOs Wait until all clocks are stable and synchronous. Hold TxCLK and RxCLK high or low Toggle TxCLK (and RxCLK) to write (and read) data at parallel bus On-chip POR circuit maintains internal reset for = 150 ms based on an internal counter monitoring the REFCLK input. SCAN25100 SNLS223C – SEPTEMBER 2006 – REVISED APRIL 2013 www.ti.com Functional Description POWER UP AND LINK SYNCHRONIZATION An internal power on reset (POR) circuit disables the transmitter output and sets receiver ROUT[9:0], LOS, LOCKB, and CDET in static high state for approximately 150 ms (150ms is based on an internal counter monitoring the 30.72 MHz RefCLK) to allow external clock sources to stabilize. A special power up sequence is not required, but a monotonic power ramp will ensure the SCAN25100 attains the proper initial state when stable supply levels within the recommended range are achieved . Once the transmitter powers up and TXCLK becomes active, the transmitter starts sending valid data. Once the receiver is powered up and REFCLK exists, the receiver is ready to receive data. When comma alignment is enabled (CALIGN_EN = 1), the receiver searches for a valid comma in the incoming stream. When a comma is detected, the receiver performs code group (comma) alignment and presents data on ROUT. To ensure the parallel bus FIFO read/write pointer distance is half of the total FIFO depth, the following procedure should be followed (e.g., after reset or comma (re)alignment): 1. Power up SCAN25100 while holding TXCLK and RXCLK (in read mode) input clocks static low or high. The SCAN25100 will hold both transmitter and receiver FIFO’s in reset until the TXCLK and RXCLK start toggling. 2. Wait for all clock sources to become synchronous and stable based on the CPRI timing specification. 3. Toggle TXCLK and RXCLK input clocks to latch data into and out of the parallel DIN/ROUT buses. 4. If at any time the clock requires a resynchronization, such as switching 30.72 MHz system clock. Holding TXCLK and RXCLK (in read mode) static high or low resets the SCAN25100 internal FIFO pointers. Figure 2. Power Up State Diagram 12 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated Product Folder Links: SCAN25100 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |