35 / 47 page ![]() Triple Channel 1°C Temperature Sensor with Hardware Thermal Shutdown and 1.8V SMBus Communications Datasheet SMSC EMC1187 35 Revision 1.0 (07-11-13) DATASHEET 6.12 Channel Mask Register 1Fh The Channel Mask Register controls individual channel masking. When a channel is masked, the ALERT pin will not be asserted when the masked channel reads a diode fault or out of limit error. The channel mask does not mask the SYS_SHDN pin. Bit 2 - E2MASK - Masks the ALERT pin from asserting when the External Diode 2 channel is out of limit or reports a diode fault. ‘0’ (default) - The External Diode 2 channel will cause the ALERT pin to be asserted if it is out of limit or reports a diode fault. ‘1’ - The External Diode 2 channel will not cause the ALERT pin to be asserted if it is out of limit or reports a diode fault. Bit 1 - E1MASK - Masks the ALERT pin from asserting when the External Diode1 channel is out of limit or reports a diode fault. ‘0’ (default) - The External Diode1 channel will cause the ALERT pin to be asserted if it is out of limit or reports a diode fault. ‘1’ - The External Diode1 channel will not cause the ALERT pin to be asserted if it is out of limit or reports a diode fault. Bit 0 - INTMASK - Masks the ALERT pin from asserting when the Internal Diode temperature is out of limit. ‘0’ (default) - The Internal Diode channel will cause the ALERT pin to be asserted if it is out of limit. ‘1’ - The Internal Diode channel will not cause the ALERT pin to be asserted if it is out of limit. 6.13 Consecutive ALERT Register 22h The Consecutive ALERT Register determines how many times an out-of-limit error or diode fault must be detected in consecutive measurements before the ALERT or SYS_SHDN pin is asserted. Additionally, the Consecutive ALERT Register controls the SMBus Timeout functionality. An out-of-limit condition (i.e. HIGH, LOW, or FAULT) occurring on the same temperature channel in consecutive measurements will increment the consecutive alert counter. The counters will also be reset if no out-of-limit condition or diode fault condition occurs in a consecutive reading. When the ALERT pin is configured as an interrupt, when the consecutive alert counter reaches its programmed value, the following will occur: the STATUS bit(s) for that channel and the last error condition(s) (i.e. E1HIGH or E2LOW and/or E2FAULT) will be set to ‘1’, the ALERT pin will be asserted, the consecutive alert counter will be cleared, and measurements will continue. Table 6.13 Channel Mask Register ADDR. R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 1Fh R/W Channel Mask - --- - E2 MASK E1 MASK INT MASK 00h Table 6.14 Consecutive ALERT Register ADDR. R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 22h R/W Consecutive ALERT TIME OUT CTHRM[2:0] CALRT[2:0] - 70h |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |