19 / 26 page ![]() STMUX1800E Electrical characteristics Doc ID 16772 Rev 3 19/26 Figure 10. Test circuit for off isolation measurement (OIRR) 1. CL includes probe and jig capacitance. 2. A 50 Ω termination resistor is needed to match the loading of the network analyzer. Off isolation is measured at the output of the OFF channel. For example, when VSEL= 0, and B is the input, the output is measured at B1. All unused analog input ports are connected to GND and output ports are left open. HP8753ES setup: Average = 4 RBW = 3 kHz VBIAS = 0.35 V ST = 2 s P1 = 0 dBm |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|