| Electronic Components Datasheet Search |
|
MP2953B Datasheet(PDF) 21 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP2953B Datasheet(HTML) 21 Page - Monolithic Power Systems |
|
21 / 30 page ![]() MP2953B – DIGITAL PWM CONTROLLER WITH PMBUS FOR VR12.5 MP2953B Rev. 1.01 www.MonolithicPower.com 21 10/9/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2015 MPS. All Rights Reserved. b) The VR latches if the input voltage is above VIN_OV_FAULT_LIMIT. c) The VR is warned if the input voltage is below VIN_UV_WARNING_LIMIT. Under Voltage: When the output voltage is below VID – 300mV for a pre-set time, the VR either latches off or re-starts depending on the user selection via the PMBus. Over Voltage: a) When the output voltage is above VID + 300mV for a pre-set time, the VR latches off (with all the low-side MOSFETs turned on). It can be programmed to re- start after the fault condition clears. b) When the output voltage is above Vout_Max + 400mV for another pre-set time, the VR latches off (with all the low- side MOSFETs turned on). Reverse Voltage: All the low-side MOSFETs turn off if the output voltage is below 30mV. Over Current: When the total current is above the OCP level for a pre-set time, the VR latches off or re-starts. Over-Temperature Indicator (VRHOT#, Active Low): When the temperature is above OTP_LIMIT, the VR latches until the temperature falls below OTP_LIMIT- OTP_HYS. Fault# Signal (CFP): When Vin is above VIN_OV_FAULT_LIMIT or the output voltage is above Vout_Max +400mV, then Fault# pulls low actively. CML: The PMBus communication fault. EEPROM Fault: The data in the EEPROM is invalid. All fault conditions can be monitored via the PMBus. OVP, OCP, and UVP modes have options of no action, latch, retry, or hiccup mode. After the fault condition clears, the MP2953B waits12.5ms before attempting to re-start again. A 12.5ms delay ensures a sufficiently low duty-cycle stress rate to prevent regulator components from being damaged by power cycling. For latched protection mode, external intervention is required to clear the latch before the VR can re-start again. External intervention includes the enable signal toggle, controller power-supply recycle, or input-voltage supply toggle. The fault status is record in the registers. Once triggered, the fault registers report faults even if the fault condition no longer exists. Fault registers may be cleared manually by issuing a fault clear command, controller power-supply cycle, or the enable signal toggle (either by EN or command enable toggle). The following is a brief description of each fault: Over-Voltage Protection (OVP) The OVP circuit monitors the output voltage for an over-voltage condition. The over-voltage signal generation is shown in Fig. 11. VID 300mV COMP VDIFF OV2 COMP OV1 COMP UV COMP RV 30mV VOSEN DAC VOUT_MAX+400mV FIGURE 11. OV, UV, and RV Signal Generation There are two levels of over-voltage protection: 1. OVP2 (VID+300mV) and 2. OVP1 (VOUT_MAX + 400mV). The OVP2 signal is blanked during the soft-start and soft-shut down process to avoid a false trigger by a pre-bias condition. Also, the OVP2 monitor is disabled during a VID decay transition. It re-activates after finishing the VR settle re- assertion transition. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |