45SD Datasheet(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
45SD Datasheet(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 6 page ![]() 9 Bus Diagnostics Register: This is a 2 byte read only register. When an error occurs, the corresponding bit is set. Byte 1 bit 0 ROM Checksum Error bit 1 not used = 0 bit 2 Off-Bus error bit 3 reserved = 0 bit 4 reserved = 0 bit 5 not used = 0 bit 6 not used = 0 bit 7 EEPROM Failure Byte 2 bit 0 not used = 0 bit 1 not used = 0 bit 2 not used = 0 bit 3 reserved = 0 bit 4 reserved = 0 bit 5 not used = 0 bit 6 Low Gain Alarm bit 7 not used = 0 10 Cyclical Timer: Setting to a non zero value will enable unsolicited WRITE-ON or WRITE-OFF messages to be transmitted with a real time interval equal to 10.24 ms times the set value. These messages will reflect the current state of the input variable (attribute #18). This attribute is stored in non volatile memory. 11 Serial Number: Unique number used to differentiate products prior to address assignment. The firm ware waits for a random period of up to 10 ms before responding to a read of this attribute. This makes it possible to detect two nodes with the same address. 12 Date Code: ASCII string that identifies date of manufacture. 13 Catalog listing: ASCII string = “Q45X, 45SD1”. 14 Vendor Name: ASCII String = “Banner Engineering”. 15 Device Name: ASCII String = “Photoelectric Sensor”. 18 Input Variable: This reflects the state of the sensors output, 0 = Dark, 1 = Light. The logical state of this attribute can be inverted by setting attribute 61, NO/NC. The state of this attribute may also be forced by using action 51, Force State. 51 Direct Input State: This is a single byte, 8 flags. bit 0 Real time sense level, high when excess gain > 1 bit 1 Real time diagnostics signal, high when excess gain > 2.5 ( Sensor sees Light and Alarm is off) bit 2-7 = 0, not used. Possible values of Attribute 51 are: 51 = 0 Dark 51 = 1 Low Gain 51 = 3 Light The NO/NC bit (attribute #60) does not affect this register. 56 Tag Name: This is a read/write 24 character ASCII string. This attribute is stored in non volatile memory. 58 Diagnostic Count Limit: Each time a low gain condition occurs, it is counted. When that count reaches the diagnos- tic count limit, the dignostic register is updated and an event 0 is sent. Here are some possible values for the diagnostic count limit: 0 = Low gain alarm disabled; 1 = Low gain bit set each time low gain condition occurs; 20 = Low gain bit is set after 20 low gain conditions. 4 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |