| Electronic Components Datasheet Search |
|
45SD Datasheet(PDF) 3 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
45SD Datasheet(HTML) 3 Page - Banner Engineering Corp. |
|
3 / 6 page ![]() SDS Model Specification for 45SD1 Bus Card The 45SD card conforms to the following SDS model: Level 4 Binary Input, 1.1.1.5 ATTRIBUTES Attribute Description R/W Data Type Size Count Default value 0 Network Data Descriptor R Uns. Byte 6 18,1,0,0,0,0 1 Baud Rate R Uns. Byte 1 0 2 Object Type R Uns. Byte 4 1,1,1,5 3 Partner ID R Uns. Word 1 50 4 Device Address R Uns. Byte 1 125 6 Unsolicited Mode Enable R/W Bool. Und 1 1 7 Software Version R Char. Und 11 38741 - X.X 8 Diagnostic Error Counter. R Uns. Byte 1 9 Diagnostic Register R/W Uns. Byte 2 10 Cyclic Timer R/W Uns. Byte 1 0 11 Serial Number R Uns. Long 1 XX...X 12 Date Code R Char. Und 4 MMYY 13 Catalog Listing R Char. Und 24 45SD1, Q45X 14 Partner Name R Char. Und 24 “Banner Engineering” 15 Component Name R Char. Und 24 “Photoelectric Sensor” 18 Input Data R Bool. Und 1 - 51 Direct Input State R Uns. Byte 1 - 56 Tag Name R/W Char. Und 24 Blank 58 Diagnostic Count Limit R/W Uns. Byte 1 1 61 Configuration Register R/W Uns. Byte 1 0 0 I/O Type: 18,1,0,0,0,0 These six bytes indicate that this is a single point binary input with the input variable at Attribute #18. 1 Baud Rate: Always returns 0. This indicates that this device automatically determines the correct baud rate for comunication. 2 Device Type: Indicates type of device in terms of the SDS protocol. This is presented as 4 X 8 bit words: 01,01,01, 05 hex. 3 Vendor Identification Number: 50 decimal. 4 Device Address : This variable indicates the devices network address 0-125. It is the logical SDS address - 1. If the SDS address of this device is 1 this attribute will be 0. Default value is 125 decimal. This attribute is stored in non volatile memory. 6 Unsolicited Mode Enable: Setting this bit allows the device to send I/O event driven messages. These event messages include: COS ON, COS OFF, WRITE ON, WRITE OFF. If this bit is cleared then only the error event (event 0) is generated, all other events will be disabled. This attribute is stored in non volatile memory. 7 Software version Number: ASCII character string “38741-X.X” 8 Diagnostic Error Counter: The Diagnostic Error counter indicates the number of errors flags that are currently set in attribute # 9. The possible values of this counter are 0,1,2,3 or 4. 3 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |