Part # DPO4USB
Description  Mixed Domain Oscilloscopes
PDF  46 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TEKTRONIX [TEKTRONIX, INC.]
Direct Link  https://www.tek.com/
Logo TEKTRONIX - TEKTRONIX, INC.

DPO4USB Datasheet(HTML) 23 Page - TEKTRONIX, INC.

Back Button DPO4USB Datasheet HTML 19Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 20Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 21Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 22Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 23Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 24Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 25Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 26Page - TEKTRONIX, INC. DPO4USB Datasheet HTML 27Page - TEKTRONIX, INC. Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 46 page
background image
Extended Video (optional)
Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/
30, 1080p/50, 1080p/60, and custom bi-level and tri-level sync video standards.
Custom bi-level and tri-level sync video standards.
Parallel (requires option
MDO4MSO)
Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits (from the digital and analog channels) in size. Binary and
Hex radices are supported.
Acquisition system
Acquisition modes
Sample
Acquire sampled values.
Peak Detect
Captures glitches as narrow as 800 ps (MDO4104C with option SA3 or SA6 and ≤ 2 channels enabled or MDO4104C without SA3
or SA6) or 1.6 ns MDO4104C with option SA3 or SA6 and ≥ 3 channels enabled and all other models) at all sweep speeds
Averaging
From 2 to 512 waveforms included in average.
Envelope
Min-max envelope reflecting Peak Detect data over multiple acquisitions. Number of waveforms in the envelope selectable
between 1 and 2000 and infinity
Hi Res
Real-time boxcar averaging reduces random noise and increases vertical resolution.
Roll
Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div.
FastAcq®
FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events, capturing >340,000 wfms/s on
1 GHz models and >270,000 wfms/s on 200 MHz - 500 MHz models.
Waveform measurements
Cursors
Waveform and Screen
DC measurement accuracy
±((DC Gain Accuracy) * |reading - (Offset - Position)| + Offset Accuracy + 0.15 div + 0.6 mV)
Automatic measurements
(time domain)
30, of which up to eight can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time,
Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive
Overshoot, Negative Overshoot, Total Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle
RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area.
Automatic measurements
(frequency domain)
3, of which one can be displayed on-screen at any one time. Measurements include Channel Power, Adjacent Channel Power
Ratio (ACPR), and Occupied Bandwidth (OBW)
Measurement statistics
Mean, Min, Max, Standard Deviation.
Reference levels
User-definable reference levels for automatic measurements can be specified in either percent or units.
Gating
Isolate the specific occurrence within an acquisition to take measurements on, using either the screen or waveform cursors.
Waveform histogram
A waveform histogram provides an array of data values representing the total number of hits inside of a user-defined region of the
display. A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be
measured.
Sources
Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math
Types
Vertical, Horizontal
Waveform histogram
measurements
12, of which up to eight can be displayed on-screen at any one time. Waveform Count, Hits in Box, Peak Hits, Median, Max, Min,
Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3
MDO4000C Series Oscilloscope
Trigger system
www.tek.com 23



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com