| Electronic Components Datasheet Search |
|
MPC92433 Datasheet(PDF) 4 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC92433 Datasheet(HTML) 4 Page - Freescale Semiconductor, Inc |
|
4 / 20 page ![]() Advanced Clock Drivers Devices 4 Freescale Semiconductor MPC92433 Table 2. Function Table Control Default(1) 1. Default states are set by internal input pull-up or pull-down resistors of 75 k Ω. 01 Inputs REF_SEL 1 Selects REF_CLK input as PLL reference clock Selects the XTAL interface as PLL reference clock M[9:0] 01 1111 0100b(2) 2. If fREF = 16 MHz, the default configuration will result in an output frequency of 250 MHz. PLL feedback divider (10-bit) parallel programming interface NA[2:0] 010 PLL post-divider parallel programming interface. See Table 9 NB 0 PLL post-divider parallel programming interface. See Table 9 P 1 PLL pre-divider parallel programming interface. See Table 8 PLOAD 0 Selects the parallel programming interface. The internal PLL divider settings (M, NA, NB and P) are equal to the setting of the hardware pins. Leaving the M, NA, NB and P pins open (floating) results in a default PLL configuration with fOUT = 250 MHz. See application/programming section. Selects the serial (I2C) programming interface. The internal PLL divider settings (M, NA, NB and P) are set and read through the serial interface. ADR[1:0] 00 Address bit = 0 Address bit = 1 SDA, SCL See Programming the MPC92433 BYPASS 1 PLL function bypassed fQA=fREF÷ NA and fQB=fREF÷ (NA· NB) PLL function enabled fQA = (fREF÷ P) · M ÷ NA and fQB = (fREF ÷ P) · M ÷ (NA · NB) TEST_EN 0 Application mode. Test mode disabled. Factory test mode is enabled CLK_STOPx 1 Output Qx is disabled in logic low state. Synchronous disable is only guaranteed if NB = 0. Output Qx is synchronously enabled MR The device is reset. The output frequency is zero and the outputs are asynchronously forced to logic low state. After releasing reset (upon the rising edge of MR and independent on the state of PLOAD), the MPC92433 reads the parallel interface (M, NA, NB and P) to acquire a valid startup frequency configuration. See application/programming section. The PLL attempts to lock to the reference signal. The tLOCK specification applies. Outputs LOCK PLL is not locked PLL is frequency locked |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |