R3-WT4B3AS Datasheet(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-WT4B3AS Datasheet(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 7 page ![]() MODEL: R3-WT4B R3-WT4B SPECIFICATIONS ES-8384 Rev.5 Page 1/7 http://www.m-system.co.jp/ Remote I/O R3 Series AC POWER INPUT MODULE (4 input circuits, clamp-on current sensor type CLSB use) 52.5 (2.07) 130 (5.12) 109 (4.29) mm (inch) MODEL: R3-WT4B[1][2][3][4] ORDERING INFORMATION • Code number: R3-WT4B[1][2][3][4] Specify a code from below for each of [1] through [4]. (e.g. R3-WT4B11W/Q) • Specify the specification for option code /Q (e.g. /C01) NO. OF CHANNELS 4B: 4 channels, Sensor type CLSB [1] CONFIGURATION 1: 3-phase / 3-wire 2: Single-phase / 2-wire 3: Single-phase / 3-wire [2] INPUT (unbalanced load) 1: 110 V AC / 50 A 2: 110 V AC / 100 A 5: 220 V AC / 50 A 6: 220 V AC / 100 A A: 200 V AC / 50 A (single-phase/3-wire) B: 200 V AC / 100 A (single-phase/3-wire) [3] COMMUNICATION MODE S: Single W: Dual [4] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating RELATED PRODUCTS • PC configurator software (model: R3CON) The R3CON is used to set up the software setting of this module. Downloadable at M-System's web site. • Clamp-on current sensor (model: CLSB-05) • Clamp-on current sensor (model: CLSB-10) Note: The clamp-on current sensor, not included in the product package of the R3 module, must be ordered separately. Refer to the data sheet for the sensor for more information such as applicable wire diameter. GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Input: M3.5 screw terminals (torque 0.8 N·m) Internal power: Via the Installation Base (model: R3-BSx) Screw terminal: Nickel-plated steel Isolation: Sensor core to sensor output or current input or internal bus or internal power to voltage input Computation: Time division multiplication DIP switch settings: • Measuring variables • Computation methods • Count Reset (Disable/Enable) • Others Refer to the instruction manual for details. RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Bi-color (red/green) LED; Red with input abnormality; Green in normal operating conditions. Power ON timer: Starts conversion in 10 seconds after the power is turned on. Low-end cutout: Converted data forced to 0 % for 2 % or less input. (Selectable by using R3CON) INPUT SPECIFICATIONS Frequency: 50 or 60 Hz • Voltage Input Operational range: 0 – 120 % of rating Overload capacity: 150 % of rating for 10 sec., 120 % continuous • Current Input |
Similar Part No. - R3-WT4B3AS |
|
Similar Description - R3-WT4B3AS |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |