Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

SST38LF6401ET Datasheet(PDF) 13 Page - Microchip Technology

Part # SST38LF6401ET
Description  64-Mbit (x16) Extended Temperature Parallel Flash Memory
PDF  47 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MICROCHIP [Microchip Technology]
Direct Link  http://www.microchip.com
Logo MICROCHIP - Microchip Technology

SST38LF6401ET Datasheet(HTML) 13 Page - Microchip Technology

Back Button SST38LF6401ET Datasheet HTML 9Page - Microchip Technology SST38LF6401ET Datasheet HTML 10Page - Microchip Technology SST38LF6401ET Datasheet HTML 11Page - Microchip Technology SST38LF6401ET Datasheet HTML 12Page - Microchip Technology SST38LF6401ET Datasheet HTML 13Page - Microchip Technology SST38LF6401ET Datasheet HTML 14Page - Microchip Technology SST38LF6401ET Datasheet HTML 15Page - Microchip Technology SST38LF6401ET Datasheet HTML 16Page - Microchip Technology SST38LF6401ET Datasheet HTML 17Page - Microchip Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 47 page
background image
 2020-2022 Microchip Technology Inc. and its subsidiaries
DS20006448B-page 13
SST38LF6401ET
Write Buffer Programming
Write to Buffer4
555H
AAH
2AAH
55H
BA
25H
BA
WC
WAX
Data
WAX
Data
WAX
Data
Program Buffer
to Flash
BAX
29H
—
—
—
—
—
—
—
—
—
—
—
—
Write to Buffer
Abort Reset
555H
AAH
2AAH
55H
555H
F0H
—
—
—
—
—
—
—
—
Bypass Mode5
Bypass Mode
Entry
555H
AAH
2AAH
55H
555H
20H
—
—
—
—
—
—
—
—
Bypass Word
Program
XXXH
A0H
—
Data
—
—
—
—
—
—
—
—
—
—
Bypass Sector
Erase
XXXH
80H
—
50H
—
—
—
—
—
—
—
—
—
—
Bypass Block
Erase
XXXH
80H
—
30H
—
—
—
—
—
—
—
—
—
—
Bypass Chip
Erase
XXXH
80H
—
10H
—
—
—
—
—
—
—
—
—
—
Bypass Mode
Exit
XXXH
90H
00H
—
—
—
—
—
—
—
—
—
—
—
Erase Related
Sector Erase
555H
AAH
2AAH
55H
555H
80H
555H
AAH
2AAH
55H
SAX
50H
—
—
Block Erase6
555H
AAH
2AAH
55H
555H
80H
555H
AAH
2AAH
55H
BAX
30H
—
—
Chip Erase
555H
AAH
2AAH
55H
555H
80H
555H
AAH
2AAH
55H
555H
10H
—
—
Erase Suspend XXXH
B0H
—
—
—
—
—
—
—
—
—
—
—
—
Erase Resume XXXH
30H
—
—
—
—
—
—
—
—
—
—
—
—
Security ID
Sec ID Entry7
555H
AAH
2AAH
55H
555H
88H
—
—
—
—
—
—
—
—
TABLE 5-2:
SOFTWARE COMMAND SEQUENCE (CONTINUED)
Command
Sequence
1st Bus
Cycle
2nd Bus
Cycle
3rd Bus Cycle 4th Bus Cycle 5th Bus Cycle 6th Bus Cycle 7th Bus Cycle
Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
Note 1:
Address format A10-A0 (Hex). Addresses A11- A21 can be VIL or VIH, but no other value, for the SST38LF6401ET com-
mand sequence.
2:
DQ15-DQ8 can be VIL or VIH, but no other value, for command sequence.
3:
All read commands are in Bold Italics.
4:
Total number of cycles in this command sequence depends on the number of words to be written to the buffer. Addi-
tional words are written by repeating Write Cycle 5. Address (WAX) values for Write Cycle 6 and later must have the
same A21-A4 values as WAX in Write Cycle 5. WC = Word Count. The value of WC is the number of words to be written
into the buffer, minus 1. Maximum WC value is 15 (i.e. F Hex)
5:
Erase Suspend and Erase Resume commands are also available in Bypass mode.
6:
For SST38LF6401ET, Sector Erase or Block Erase can be used to erase sectors S1016 - S1023. Use address SAx.
Block Erase cannot be used to erase all 32 kW of Block B127. For SST38LF6401ET, Sector Erase or Block Erase can
be used to erase sectors S0-S7. Use address SAx. Block Erase cannot be used to erase all 32 kW of Block B0.
7:
Once in Sec ID mode, the Word Program, Write Buffer Programming and Bypass Word Program features can be used
to program the Sec ID area.
8:
Unique ID is read with A3 = 0 (Address range = 000000H to 000007H), User portion of Sec ID is read with A8 = 1
(Address range = 000100H to 0001FFH). Lock-out status is read with A7-A0 = FFH. Unlocked: DQ3 = 1/Locked:
DQ3 = 0. Lock status can also be checked by reading Bit ‘0’ in the PSR.
9:
Both Software ID Exit operations are equivalent.
10: If bits are not locked, then the user-programmable portion of the Sec ID can be programmed over the previously unpro-
grammed bits (Data = 1) using the Sec ID mode again (bits programmed ‘0’ cannot be reversed to ‘1’). Valid Word
Addresses for the user-programmable portion of the Sec ID are from 000100H-0001FFH.
11: The device does not remain in Software Product ID Mode if powered down.
12: With AMS-A1 = 0; Manufacturer ID = 00BFH, is read with A0 = 0, SST38LF6401ET Device ID = 536B, is read with
A0 =1.
13: CFI Query Entry and SST CFI Query Entry are equivalent. Both allow access to the same CFI tables.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com