| Electronic Components Datasheet Search |
|
L9908 Datasheet(PDF) 71 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9908 Datasheet(HTML) 71 Page - STMicroelectronics |
|
71 / 153 page ![]() Figure 44. n-th Current Monitor Channel simplified block diagram Each current monitor channel can be used to measure positive or negative motor current flow through single (DC Link) or multiple (Single Leg) shunts system configurations. Figure 45. External Shunts Configurations a) DC-Link, b) 2xSingle Leg + DC-Link, c) 3xSingle Leg The specific n-th current monitor channel can be disabled by a dedicated SPI bit in the SAFETY_RELEVANT2 register, as follows: Table 68. n-th Current Monitor Channel enable bit CSn_DIS Description 0 n-th current monitor enabled (Default) 1 n-th current monitor disabled When disabled, the n-th input current measurement structure is set in low consumption mode, the related DSP logic is reset and the output stage is set into high impedance state. The current monitor channel consists of three main parts: • A/D Conversion; • Digital Signal Processing; • D/A Conversion. L9908 Current monitors DS13546 - Rev 3 page 71/153 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|