| Electronic Components Datasheet Search |
|
SHT35-DIS Datasheet(PDF) 4 Page - Sensirion AG Switzerland |
|
|
|||||||||||||||||||||||||||||
SHT35-DIS Datasheet(HTML) 4 Page - Sensirion AG Switzerland |
|
4 / 26 page ![]() www.sensirion.com / D1 Version 1 – December 2022 4/26 1 Humidity and Temperature Sensor Specifications Every SHT33 is individually tested and calibrated and is identifiable by its unique serial number (see section 4.11 for details on the serial number). For the calibration, Sensirion uses transfer standards, which are subject to a scheduled calibration procedure. The calibration of the reference, used for the calibration of the transfer standards, is NIST traceable through an ISO/IEC 17025 accredited laboratory. 1.1 Relative Humidity Parameter Conditions Value Units SHT RH accuracy1 typ. 2 %RH max. see Figure 1 - Repeatability2, 3 high 0.08 %RH medium 0.15 %RH low 0.21 %RH Resolution4 Typ. 0.01 %RH Specified range5 extended6 0 to 100 %RH Response time7 ������63% 88 s Long-term drift9 typ. <0.25 %RH/y Table 1. General relative humidity sensor specifications. Figure 1. Maximal and typical tolerance of RH at 25°C 1 For definition of typ. and max. accuracy, please refer to the document “Sensirion Humidity Sensor Specification Statement”. [6] 2 The stated repeatability is 3 times the standard deviation (3σ) of multiple consecutive measurements at the stated repeatability and at constant ambient conditions. It is a measure for the noise on the physical sensor output. Different measurement modes allow for high/medium/low repeatability 3 Valid for 25 °C and 50 %RH. 4 Resolution of A/D converter. 5 Specified range refers to the range for which the humidity or temperature sensor specification is guaranteed. 6 For details about recommended humidity and temperature operating range, please refer to section 1.3. 7 Time for achieving 63% of a humidity step function, measured at 25 °C and 1 m/s airflow. Humidity response time in the application depends on the design-in of the sensor. 8 With activated ART function (see section 4.7 ) the response time can be improved by a factor of two. 9 Typical value for operation in normal RH/T operating range. Value may be higher in environments with vaporized solvents, out-gassing tapes, adhesives, pacore details please refer to Handling Instructions. [4] ±0 ±2 ±4 ±6 ±8 0 10 20 30 40 50 60 70 80 90 100 Relative Humidity (%RH) maximal tolerance typical tolerance DRH (%RH) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |