| Electronic Components Datasheet Search |
|
P89LPC9401 Datasheet(PDF) 39 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
P89LPC9401 Datasheet(HTML) 39 Page - NXP Semiconductors |
|
39 / 59 page ![]() P89LPC9401_1 © Koninklijke Philips Electronics N.V. 2005. All rights reserved. Preliminary data sheet Rev. 01 — 5 September 2005 39 of 59 Philips Semiconductors P89LPC9401 8-bit two-clock 80C51 microcontroller with 32 segment × 4 LCD driver 7.26.11 Output bank selector The LCD controller includes a RAM bank switching feature in the static and 1:2 drive modes. In the static drive mode, the BANK SELECT command may request the contents of bit 2 to be selected for display instead of the contents of bit 0. In 1:2 mode, the contents of bits 2 and 3 may be selected instead of bits 0 and 1. This allows display information to be prepared in an alternative bank and then selected for display when it is assembled. 7.26.12 Input bank selector The input bank selector loads display data into the display RAM based on the selected LCD drive configuration. The BANK SELECT command can be used to load display data in bit 2 in static drive mode or in bits 2 and 3 in 1:2 mode. The input bank selector functions are independent of the output bank selector. 7.26.13 Blinker The LCD controller has a very versatile display blinking capability. The whole display can blink at a frequency selected by the BLINK command. Each blink frequency is a multiple integer value of the clock frequency; the ratio between the clock frequency and blink frequency depends on the blink mode selected, as shown in Table 8. An additional feature allows an arbitrary selection of LCD segments to be blinked in the static and 1 : 2 drive modes. This is implemented without any communication overheads by the output bank selector which alternates the displayed data between the data in the display RAM bank and the data in an alternative RAM bank at the blink frequency. This mode can also be implemented by the BLINK command. The entire display can be blinked at a frequency other than the nominal blink frequency by sequentially resetting and setting the display enable bit E at the required rate using the MODE SET command. Blink modes 0.5 Hz, 1 Hz and 2 Hz, and nominal blink frequencies 0.5 Hz, 1 Hz and 2 Hz correspond to an oscillator frequency (fosc(LCD)) of 1536 Hz at pin CLK. The oscillator frequency range is 397 Hz to 3046 Hz. 7.26.13.1 I2C-bus controller The LCD controller acts as an I2C-bus slave receiver. In the P89LPC9401 the hardware subaddress inputs A0, A,1 and A2 are tied to VSS setting the hardware subaddress = 0. 7.26.14 Input filters To enhance noise immunity in electrically adverse environments, RC low-pass filters are provided on the SDA and SCL lines. Table 8: Blinking frequencies Blink mode Normal operating mode ratio Normal blink frequency Off - Blinking off 2 Hz fosc(LCD) / 768 2 Hz 1Hz fosc(LCD) / 1536 1 Hz 0.5 Hz fosc(LCD) / 3072 0.5 Hz |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |