Back Button PINA745AIRELR Datasheet HTML 12Page - Texas Instruments PINA745AIRELR Datasheet HTML 13Page - Texas Instruments PINA745AIRELR Datasheet HTML 14Page - Texas Instruments PINA745AIRELR Datasheet HTML 15Page - Texas Instruments PINA745AIRELR Datasheet HTML 16Page - Texas Instruments PINA745AIRELR Datasheet HTML 17Page - Texas Instruments PINA745AIRELR Datasheet HTML 18Page - Texas Instruments PINA745AIRELR Datasheet HTML 19Page - Texas Instruments PINA745AIRELR Datasheet HTML 20Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 50 page
background image
of averages is achieved. After all of the samples have been measured, the average current and voltage is
determined, the power is calculated, and the results are loaded to the corresponding output registers where they
can then be read.
The energy and charge values are accumulated for each conversion cycle. Therefore the INA745x averaging
function is not applied to these.
Calculations for power, charge and energy are performed in the background and do not add to the overall
conversion time.
i
v
T
i
v
i
v
i
v
i
v
i
p1
p2
p3
p4
p5
Q1 =
i1 x t1
Q.. =
i.. x t..
Q.. =
i.. x t..
Q.. =
i.. x t..
Q.. =
i.. x t..
E.. =
p.. x t..
E.. =
p.. x t..
E.. =
p.. x t..
E.. =
p.. x t..
E1 =
p1 x t2
Power register
Energy register
Charge register
T
T
T
T
ADC,
Temperature, Current,
Voltage
T
Figure 6-7. Power, Energy and Charge Calculation Scheme
6.3.5 High-Precision Delta-Sigma ADC
The integrated ADC is a high-performance, low-offset, low-drift, delta-sigma ADC designed to support
bidirectional current measurement. The measured inputs are selected through the high-voltage input multiplexer
to the ADC inputs (see Figure 6-6). The ADC architecture enables lower drift measurement across temperature
and consistent offset measurements across common-mode voltage, temperature, and power supply variations. A
low-offset ADC is preferred in current sensing applications to provide a near 0 V offset voltage that maximizes
the useful dynamic range of the system.
The INA745x measures the die temperature, current, and bus voltage. An internal temperature measurement is
made before each current measurement. Temperature compensation is then applied to the current measurement
to achieve low drift performance. The MODE bits setting in the ADC_CONFIG register permit selecting modes
to convert only the current or bus voltage to further allow the user to configure the monitoring function to fit
the specific application requirements. After an ADC conversion is complete, the converted values independently
update in their corresponding registers where they can be read through the digital interface at the time of
conversion end if no averaging is selected.
The conversion times for shunt voltage, bus voltage, and temperature inputs are set independently from 50
µs to 4.12 ms depending on the values programmed in the ADC_CONFIG register. The value for current is
calculated after both the temperature and shunt voltage measurements are made. The total time to get the
current measurement is the sum of the conversion times for these two parameters. Enabled measurement inputs
are converted sequentially, which means the total time to convert all inputs depends on the conversion time for
each input and the number of inputs enabled. When averaging is used, the intermediate values are subsequently
stored in an averaging accumulator, and the conversion sequence repeats until the number of averages is
reached. After all of the averaging is complete, the final values are updated in the corresponding registers that
can then be read. These values remain in the data output registers until they are replaced by the next fully
completed conversion results. In this case, reading the data output registers does not affect a conversion in
progress.
The ADC has two conversion modes—continuous and triggered—set by the MODE bits in the ADC_CONFIG
register. In continuous-conversion mode, the ADC will continuously convert the input measurements and update
the output registers as described above in an indefinite loop. In triggered-conversion mode, the ADC will convert
the input measurements as described above, after which the ADC will go into shutdown mode until another
single-shot trigger is generated by writing to the MODE bits. Writing the MODE bits will interrupt and restart
INA745A, INA745B
SBOSAC3A – JULY 2023 – REVISED DECEMBER 2023
www.ti.com
16
Submit Document Feedback
Copyright © 2023 Texas Instruments Incorporated
Product Folder Links: INA745A INA745B



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com