| Electronic Components Datasheet Search |
|
PINA745AIRELR Datasheet(PDF) 37 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PINA745AIRELR Datasheet(HTML) 37 Page - Texas Instruments |
|
37 / 50 page ![]() 7.5.1.10 Current Over-Limit Threshold (COL) Register (Address = Ch) [reset = 7FFFh] If negative values are entered in this register, then a current measurement of 0 A will trip this alarm. When using negative values for the undercurrent and overcurrent thresholds be aware that the overcurrent threshold must be set to the larger (that is, less negative) of the two values. The COL register is shown in Table 7-16. Return to the Summary Table. Table 7-16. COL Register Field Descriptions Bit Field Type Reset Description 15-0 COL R/W 7FFFh Sets the threshold for comparison of the value to detect over current condition (overcurrent protection). Two's complement value. Conversion factor: 1.2 mA/LSB 7.5.1.11 Current Under-Limit Threshold (CUL) Register (Address = Dh) [reset = 8000h] The CUL register is shown in Table 7-17. Return to the Summary Table. Table 7-17. CUL Register Field Descriptions Bit Field Type Reset Description 15-0 CUL R/W 8000h Sets the threshold for comparison of the value to detect undercurrent condition. Two's complement value. Conversion factor: 1.2 mA/LSB 7.5.1.12 Bus Overvoltage Threshold (BOVL) Register (Address = Eh) [reset = 7FFFh] The BOVL register is shown in Table 7-18. Return to the Summary Table. Table 7-18. BOVL Register Field Descriptions Bit Field Type Reset Description 15 Reserved R 0h Reserved. Always reads 0. 14-0 BOVL R/W 7FFFh Sets the threshold for comparison of the value to detect Bus Overvoltage (overvoltage protection). Unsigned representation, positive value only. Conversion factor: 3.125 mV/LSB. 7.5.1.13 Bus Undervoltage Threshold (BUVL) Register (Address = Fh) [reset = 0h] The BUVL register is shown in Table 7-19. Return to the Summary Table. Table 7-19. BUVL Register Field Descriptions Bit Field Type Reset Description 15 Reserved R 0h Reserved. Always reads 0. 14-0 BUVL R/W 0h Sets the threshold for comparison of the value to detect Bus Undervoltage (undervoltage protection). Unsigned representation, positive value only. Conversion factor: 3.125 mV/LSB. www.ti.com INA745A, INA745B SBOSAC3A – JULY 2023 – REVISED DECEMBER 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 37 Product Folder Links: INA745A INA745B |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |