Back Button ATA658X Datasheet HTML 28Page - Microchip Technology ATA658X Datasheet HTML 29Page - Microchip Technology ATA658X Datasheet HTML 30Page - Microchip Technology ATA658X Datasheet HTML 31Page - Microchip Technology ATA658X Datasheet HTML 32Page - Microchip Technology ATA658X Datasheet HTML 33Page - Microchip Technology ATA658X Datasheet HTML 34Page - Microchip Technology ATA658X Datasheet HTML 35Page - Microchip Technology ATA658X Datasheet HTML 36Page - Microchip Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 32 / 115 page
background image
ATA658x Data Sheet
Functional Description
Complete Data Sheet
© 2024 Microchip Technology Inc. and its subsidiaries
DS20006830B - 32
Any valid wake-up pattern (according to ISO 11898-2:2016) will trigger a wake-up event if selective
wake up is disabled (CPNE = 0), or partial networking is not configured correctly (PNCFOK = 0) and
the CAN transceiver is in TXD Standby mode with wake up enabled (CWUE = 1).
All wake-up patterns will be ignored, if the CAN transceiver is in CAN Normal/Silent mode or CAN
wake up is disabled (CWUE = ‘0’).
2.4.2.2.2 CAN Selective Wake Up and CAN FD
CAN Flexible Data-Rate (CAN FD) is an improved CAN protocol with regard to bandwidth and
payload. As specified in ISO 11898-1:2015, CAN FD is based on the CAN protocol and still uses the
same arbitration method. However, after the arbitration phase, the data rate is increased and the
data bits are transferred with a higher bit rate than in the arbitration phase. At the CRC delimiter,
before the controllers transmit the Acknowledge bits, the bit rate is switched back to the same bit
rate as used in the arbitration phase. Besides the increased bit speed, CAN FD allows data frames up
to 64 bytes compared to the maximum of 8 bytes for classical CAN.
The ATA658x can be configured to recognize CAN FD frames as valid frames. When CFDPE = 1, the
error counter is decremented every time the control field of a CAN FD frame is received. The device
remains in Sleep mode with partial networking enabled. CAN FD frames are never recognized as
valid wake-up frames, even if PNDM = 0 and the frame contains a valid ID. After receiving the control
field of a CAN FD frame, the device ignores further bus signals until Idle is again detected.
When CFDPE is set to ‘0’, CAN FD frames are interpreted as frames with errors by the partial
networking module. Therefore, the error counter is incremented when a CAN FD frame is received.
Bit PNEFD is set to ‘1’ and the device wakes up if error the counter overflows.
2.4.2.3 Remote Wake-up Pattern According to ISO 11898-2:2016
If the CAN transceiver is in TRX Standby mode and CAN bus wake up is enabled (CWUE = 1), but
CAN selective wake up is disabled (CPNE = 0 or PNCFOK = 0), the device will monitor the bus for a
standard wake-up pattern as specified in ISO11898-2:2016.
This filtering helps avoid spurious wake-up events, which could be triggered by, for example, a
dominant clamped bus or by dominant phases due to noise, spikes on the bus, transients or EMI.
The wake-up pattern consists of two dominant bus levels for a duration of at least tFilter, each
separated by a recessive bus level with a duration of at least tFilter. Dominant or recessive bits in
between the above mentioned phases that are shorter in duration than tFilter are ignored.
The complete dominant-recessive-dominant pattern, as shown in Figure 2-6, must be received
within tWake to be recognized as a valid wake-up pattern. Otherwise, the internal wake-up logic is
reset. The complete wake-up pattern will then need to be retransmitted to trigger a wake-up event.
When a valid CAN WUP is detected on the bus, the wake-up bit CWUS in the Transceiver Event Status
register is set (see section 2.4.5.6. CTRXESR) and pin RXD is driven low.
CAN wake up via WUP can only be disabled via bit CWUE. If CWUE is set to ‘0’, no remote wake up via
the CAN bus is possible. If CWUE is set to ‘1’ and selective wake up is disabled, the device will switch
to Standby mode after detecting the Wake-up Pattern (WUP) coming from Sleep mode. If CWUE is
set to ‘1’ and the selective wake-up is enabled, the device will first switch on the bus biasing after
detecting the WUP and will only switch afterward to Standby mode when it detects a valid WUF (This
is descibed in chapter 2.4.2.2. Remote Wake-up Frame According to ISO 11898-2:2016).
The figure below illustrates the control of the bus biasing and the WUP detection.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com