| Electronic Components Datasheet Search |
|
ATA658X Datasheet(PDF) 32 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
ATA658X Datasheet(HTML) 32 Page - Microchip Technology |
|
32 / 115 page ![]() ATA658x Data Sheet Functional Description Complete Data Sheet © 2024 Microchip Technology Inc. and its subsidiaries DS20006830B - 32 Any valid wake-up pattern (according to ISO 11898-2:2016) will trigger a wake-up event if selective wake up is disabled (CPNE = 0), or partial networking is not configured correctly (PNCFOK = 0) and the CAN transceiver is in TXD Standby mode with wake up enabled (CWUE = 1). All wake-up patterns will be ignored, if the CAN transceiver is in CAN Normal/Silent mode or CAN wake up is disabled (CWUE = ‘0’). 2.4.2.2.2 CAN Selective Wake Up and CAN FD CAN Flexible Data-Rate (CAN FD) is an improved CAN protocol with regard to bandwidth and payload. As specified in ISO 11898-1:2015, CAN FD is based on the CAN protocol and still uses the same arbitration method. However, after the arbitration phase, the data rate is increased and the data bits are transferred with a higher bit rate than in the arbitration phase. At the CRC delimiter, before the controllers transmit the Acknowledge bits, the bit rate is switched back to the same bit rate as used in the arbitration phase. Besides the increased bit speed, CAN FD allows data frames up to 64 bytes compared to the maximum of 8 bytes for classical CAN. The ATA658x can be configured to recognize CAN FD frames as valid frames. When CFDPE = 1, the error counter is decremented every time the control field of a CAN FD frame is received. The device remains in Sleep mode with partial networking enabled. CAN FD frames are never recognized as valid wake-up frames, even if PNDM = 0 and the frame contains a valid ID. After receiving the control field of a CAN FD frame, the device ignores further bus signals until Idle is again detected. When CFDPE is set to ‘0’, CAN FD frames are interpreted as frames with errors by the partial networking module. Therefore, the error counter is incremented when a CAN FD frame is received. Bit PNEFD is set to ‘1’ and the device wakes up if error the counter overflows. 2.4.2.3 Remote Wake-up Pattern According to ISO 11898-2:2016 If the CAN transceiver is in TRX Standby mode and CAN bus wake up is enabled (CWUE = 1), but CAN selective wake up is disabled (CPNE = 0 or PNCFOK = 0), the device will monitor the bus for a standard wake-up pattern as specified in ISO11898-2:2016. This filtering helps avoid spurious wake-up events, which could be triggered by, for example, a dominant clamped bus or by dominant phases due to noise, spikes on the bus, transients or EMI. The wake-up pattern consists of two dominant bus levels for a duration of at least tFilter, each separated by a recessive bus level with a duration of at least tFilter. Dominant or recessive bits in between the above mentioned phases that are shorter in duration than tFilter are ignored. The complete dominant-recessive-dominant pattern, as shown in Figure 2-6, must be received within tWake to be recognized as a valid wake-up pattern. Otherwise, the internal wake-up logic is reset. The complete wake-up pattern will then need to be retransmitted to trigger a wake-up event. When a valid CAN WUP is detected on the bus, the wake-up bit CWUS in the Transceiver Event Status register is set (see section 2.4.5.6. CTRXESR) and pin RXD is driven low. CAN wake up via WUP can only be disabled via bit CWUE. If CWUE is set to ‘0’, no remote wake up via the CAN bus is possible. If CWUE is set to ‘1’ and selective wake up is disabled, the device will switch to Standby mode after detecting the Wake-up Pattern (WUP) coming from Sleep mode. If CWUE is set to ‘1’ and the selective wake-up is enabled, the device will first switch on the bus biasing after detecting the WUP and will only switch afterward to Standby mode when it detects a valid WUF (This is descibed in chapter 2.4.2.2. Remote Wake-up Frame According to ISO 11898-2:2016). The figure below illustrates the control of the bus biasing and the WUP detection. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |