| Electronic Components Datasheet Search |
|
ATA658X Datasheet(PDF) 14 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
ATA658X Datasheet(HTML) 14 Page - Microchip Technology |
|
14 / 115 page ![]() ATA658x Data Sheet Pin Configuration Complete Data Sheet © 2024 Microchip Technology Inc. and its subsidiaries DS20006830B - 14 resistor), the LIN/LIN2 output transistor is turned off and the bus is in the recessive state. If the TXD_LIN/TXD_LIN2 pin stays at logic low level while switching into Normal mode, it must be pulled to high level longer than 10 μs before the LIN/LIN2 driver can be activated. This feature prevents the bus line from accidentally being driven to dominant state after Normal mode has been activated (also in case of a short circuit at TXD_LIN/TXD_LIN2 to GND). During Fail-Safe mode (LIN2 device only), the TXD_LIN2 pin is used as an output and signals, together with the RXD_LIN2 pin, the Fail-Safe source. The TXD_LIN/TXD_LIN2 input has an internal pull-up resistor. An internal timer prevents the bus line from permanently being driven to the dominant state. If TXD_LIN/TXD_LIN2 is driven to low longer than tto(dom)_LIN, the LIN/LIN2 bus driver is switched to the recessive state. Nevertheless, when switching to Sleep mode, the actual level at the TXD_LIN/TXD_LIN2 pin is relevant. Refer to 2.12.1. LIN2 Operating Modes for more information. To reactivate the LIN bus driver, switch TXD_LIN/TXD_LIN2 to high for at least tDTOrel. 1.19 RXD_LIN/RXD_LIN2 In Normal mode, this pin reports the state of the LIN/LIN2 bus to the microcontroller. LIN/LIN2 high (recessive state) is indicated by a high level at RXD_LIN/RXD_LIN2; LIN/LIN2 low (dominant state) is indicated by a low level at RXD_LIN/RXD_LIN2. The output is a push-pull stage switching between VCC/VCC_µC and GND. The AC characteristics are measured with an external load capacitor of 20 pF. If the LIN2 device is in Silent mode, the RXD_LIN2 output switches to high. 1.20 LIN/LIN2 A low-side driver with internal current limitation and thermal shutdown as well as an internal pull-up resistor, according to LIN specification 2.x/ISO 17987-4, is implemented. The voltage range is from –27V to +40V. This pin exhibits no reverse current from the LIN/LIN2 bus to VS/VS2, even in the event of a GND shift or VBat disconnection. The LIN/LIN2 receiver thresholds comply with the LIN specification. The fall time (from recessive to dominant) and the rise time (from dominant to recessive) are slope-controlled. During a short circuit at LIN/LIN2 to VBat, the output limits the output current to IBUS_LIM. If due to the power dissipation, the chip temperature exceeds TLINoff, then the LIN/LIN2 output is switched off. Once the chip cools down and after a hysteresis of Thys, the LIN/LIN2 output switches on again. RXD_LIN/RXD_LIN2 will be driven high when LIN/LIN2 is high. The VCC/VCC_µC regulator operates independently of LIN/LIN2 overtemperature shutdown. Despite a short circuit from LIN/LIN2 to GND, the IC can be switched into Sleep or Silent mode (LIN2 device only). If the short circuit disappears, the IC can be woken up via a remote wake up. The reverse current is < 2μA at pin LIN/LIN2 during loss of VBat. This is optimal behavior for bus systems where some LIN nodes are supplied from battery or ignition. 1.21 EN_LIN2 (Only ATA6582/3/7/8) The enable input pin controls the operating mode of the LIN2 device. If EN_LIN2 is high, the LIN2 device is in Normal mode, with the transmission paths from TXD_LIN2 to LIN2 and from LIN2 to RXD_LIN2 both active. The VCC_µC voltage regulator operates with 3.3V/5V 85mA output capability. If EN_LIN2 is switched to low while TXD_LIN2 is still high, the LIN2 device is forced to Silent mode and no data transmission is then possible. Refer to 2.12.1. LIN2 Operating Modes for more information. If EN_LIN2 is switched to low while TXD_LIN2 is low, the LIN2 device transitions to Sleep mode. No data transmission/reception is possible, and the VCC_µC voltage regulator is switched off. The EN_LIN2 pin provides a pull-down resistor to force the LIN2 transceiver into Recessive mode if EN_LIN2 is disconnected. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |