| Electronic Components Datasheet Search |
|
RE46C191 Datasheet(PDF) 21 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
RE46C191 Datasheet(HTML) 21 Page - Microchip Technology |
|
21 / 44 page ![]() 2013-2023 Microchip Technology Inc. and its subsidiaries DS20005225H-page 21 RE46C191 4.3 Smoke Calibration A separate Calibration mode is entered for each Measurement mode (Normal, Hysteresis, Hush and Chamber Test), so that independent limits can be set for each. In all Calibration modes, the integrator output can be accessed at the GLED output. The Gamp output voltage, which represents the smoke detection level, can be accessed at the RLED output. The SmkComp output voltage is the result of the comparison of Gamp with the integrator output and can be accessed at HB. The FEED input can be clocked to step up the smoke detection level at RLED. Once the desired smoke threshold is reached, the TEST input is pulsed low-to-high to store the result. The procedure is described in the following steps: 1. Power up with the bias conditions shown in Figure 4-1. 2. Drive TEST2 input from VSS to VDD to enter Programming mode. TEST2 remains at VDD through Step 8 described below. 3. Apply three clock pulses to the TEST input to enter T3 mode. This initiates the Calibration mode for normal limits setting. The integrator output appears at GLED and the smoke detec- tion level at RLED. 4. At this point, clock FEED to increase the smoke detection level as needed. Pulling IO high with FEED at a high logic level initiates an integration. The integrator output signal appears at GLED. The sequence of incrementing the limit, performing an integration and monitoring the HB output for the resulting comparison, can be repeated until the desired threshold is reached. Once the desired smoke threshold is reached, with FEED held low, the IO input must be pulsed low-to-high to latch the smoke detection level. 5. Apply a fourth clock pulse to the TEST input to enter T4 mode. This initiates the Calibration mode for hysteresis limits. The sequence in Step 4 must be repeated to set the hysteresis limit. 6. Apply a clock pulse to the TEST input again to enter T5 mode and initiate calibration for hush limits. Repeat Step 4 to set the hush limit. 7. Apply clock pulse to the TEST input a sixth time to enter T6 mode and initiate calibration for chamber test limits. Repeat Step 4 to set the chamber test limit. 8. After pulsing the IO input to latch the chamber test limit, the IO must be pulsed low-to-high a second time to store the limits in memory. FIGURE 4-4: Timing Diagram for Modes T3 to T6 Limits Setting. GLED IRED RLED HB IO TEST FEED TEST2 Mode T3 – T6 – Limits Setting VSS VSS VBST VSS VBST VSS VSS VSS VBST VDD VSS VBST VSS VDD Min Tsetup2 = 2 µs Min PW3 = 100 µs Min Td2 = 10 µs Min PW1 = 10 µs Min T1 = 20 µs Min PW4 = 2 ms Min PW2 = 10 ms |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |