TMP118MA Datasheet(HTML) 16 Page - Texas Instruments |
|
16 / 43 page ![]() 1 second 1 Conversion ≅11ms Standby Standby Temperature result stored Standby Standby Figure 7-2. Conversion (1Hz Conversion Rate Example) With No Averaging • Back-to-back Averaging [01b or 10b]: The device accumulates and stores a number of temperature conversion results and reports the average of all the stored results at the end of the process. If AVG [3:2] is set to 01b, 4 conversions are executed back-to-back in every conversion period and the average temperature result is stored into the Temp_Result register after the 4 conversions are completed. If AVG [3:2] is set to 10b, 8 conversions are executed back-to-back in every conversion period and the average temperature result is stored into the Temp_Result register after the 8 conversions are completed. The Back-to-back Averaging feature is useful to reduce the impact from the internal noise sources of the device, such as the device thermal noise and ADC quantization noise. Figure 6-8 and Figure 6-9 illustrates the improved noise performance of the device as a result of turning on the 8x regular averaging. Note Back-to-back Averaging increases the average current consumption of the device due to increased active conversion time in every conversion period. 1 second 4 Conversion ≅44ms Standby Standby Temperature result stored Standby Standby Temperature result stored Temperature result stored Temperature result stored Figure 7-3. Conversion (1Hz Conversion Rate Example) With 4x Back-to-Back Averaging • Moving 4x Averaging [11b]: If AVG [3:2] is set to 11b, the device performs 1 single conversion per conversion period, and the new temperature result is averaged together with the results from the 3 previous conversion period and stored into the Temp_Result register. The moving averaging feature can be beneficial to filter out fluctuation of external temperature source by taking multiple samples and averaging out the result. 1 second 1 Conversion ≅11ms Standby Standby Average of n-2, n-1, n, and n+1 conversion result stored Standby Standby nth conversion (n+1)th conversion (n+2)th conversion (n+3)th conversion (n+4)th conversion Average of n-1, n, n+1, and n+2 conversion result stored Average of n, n+1, n+2, and n+3 conversion result stored Average of n-3, n-2, n-1, and n conversion result stored Figure 7-4. Conversion (1Hz Conversion Period) With 4x Running Averaging Note Averaging can be used in both the continuous conversion mode and the one-shot mode. Note for the two faster conversion rate settings (Conversion_Rate[1:0]= 10b (15.625ms / 64Hz) or 11b (7.812ms / 128Hz)), 4x Averaging and 8x Averaging cannot be applied due to timing violation. Programming the AVG[1:0] setting to 4x Averaging (01b) or 8x Averaging (10b) causes the device to automatically revert to the 1Hz conversion rate. Using the Moving 4x Averaging (AVG[1:0]= 11b) setting is recommended if averaging feature is desired for the two faster conversion rate settings. TMP118 SNIS237A – DECEMBER 2024 – REVISED APRIL 2025 www.ti.com 16 Submit Document Feedback Copyright © 2025 Texas Instruments Incorporated Product Folder Links: TMP118 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |