| Electronic Components Datasheet Search |
|
TMP118MA Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP118MA Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 43 page ![]() Start of conversion Ac ve conversion me (tACT) Shutdown I 2C One-Shot Command Temp_Result Updated Figure 7-12. One-Shot Timing Diagram 7.5 Programming 7.5.1 I2C and SMBus Interface 7.5.1.1 Serial Interface The TMP118 has a standard bidirectional I2C interface that is controlled by a controller device. Each target on the I2C bus has a specific device address to differentiate between other target devices that are on the same I2C bus. Many target devices require configuration upon start-up to set the behavior of the device. This is typically done when the controller accesses internal register maps of the target, which have unique register pointers. The TMP118 supports transmission data rates up to 1MHz. 7.5.1.1.1 Bus Overview The physical I2C interface consists of the serial clock (SCL) and serial data (SDA) lines. Both SDA and SCL lines must be connected to a supply through an external pullup resistor (unless integrated within the controller). The size of the pullup resistor is determined by the amount of capacitance on the I2C lines, the pullup bus voltage, and the communication frequency. For further details, see the I2C Pullup Resistor Calculation application note. Data transfer can be initiated only when the bus is idle. A bus is considered idle if both SDA and SCL lines are high after a STOP condition. I2C communication with this device is initiated by the controller sending a START condition and terminated by the controller sending a STOP condition. A high-to-low transition on the SDA line while the SCL is high defines a START condition. A low-to-high transition on the SDA line while the SCL is high defines a STOP condition. A repeated START condition is similar to a START condition and is used in place of a back-to-back STOP then START condition. A repeated START condition looks identical to a START condition, but differs from a START condition because the condition occurs without a STOP condition (when the bus is not idle). www.ti.com TMP118 SNIS237A – DECEMBER 2024 – REVISED APRIL 2025 Copyright © 2025 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: TMP118 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |