| Electronic Components Datasheet Search |
|
HV110-SM02-R Datasheet(PDF) 3 Page - Superior Sensors Technology. |
|
|
|||||||||||||||||||||||||||||
HV110-SM02-R Datasheet(HTML) 3 Page - Superior Sensors Technology. |
|
3 / 17 page ![]() HV Series Differential Low Pressure Sensors www.SuperiorSensors.com 3 DS‐0001G.DOCX 5 Feature List Parameter Sym HV160 HV120 HV110 HV210 Units Notes Number of FS Pressure Ranges PNUM 8 4 5 7 Each Specified FS Range Extents PEXT ±2.5 to ±60 ±2.5 to ±20 ±0.5 to ±10 ±0.1 to ±10 inH2O Number of BW Filter Corners BWNUM 7 Each BW Corner Frequency Extents fBWEXT 0.1 to 10 Hz Common Mode Pressure PCM 700 500 500 500 inH2O 1 Proof Pressure PPROOF 400 40 40 40 inH2O 2 Burst Pressure PBURST 480 120 120 120 inH2O 3 1) Pressure applied to both ports simultaneously without incurring part damage. 2) Pressure at which the sensor will not suffer permanent damage. 3) Pressure if exceeded could cause permanent damage to the sensor. 6 Performance Characteristics Note: Unless otherwise specified, characteristics specified with VDD = 3.3V, TA = 25C Parameter Sym HV160 HV110/HV120 HV210 Units Notes Min Typ Max Min Typ Max Min Typ Max Accuracy PACC ‐ 0.05 0.1 ‐ 0.05 0.1 ‐ 0.05 0.1 % RNG 1, 2 Total Error Band TEB ‐ 0.1 0.3 ‐ 0.1 0.3 ‐ 0.05 0.15 % FSS 3 Long Term Stability LTS ‐ 0.1 0.25 ‐ 0.1 0.25 ‐ 0.05 0.1 % FSS/Yr Thermal Hysteresis THYS ‐ 0.05 ‐ ‐ 0.05 ‐ ‐ 0.025 ‐ % FSS Pressure Hysteresis PHYS ‐ 0.05 ‐ ‐ 0.05 ‐ ‐ 0.05 ‐ % RNG 1 Position Sensitivity PPS ‐ 2.0 ‐ ‐ 2.0 ‐ ‐ 0.25 ‐ Pa Supply Rejection PSR ‐ 0.0005 ‐ ‐ 0.0005 ‐ ‐ 0.0005 ‐ Pa/mV Resolution RES ‐ 16 ‐ ‐ 16 ‐ ‐ 16 ‐ bit 4 System ENOB ENOB ‐ 17 ‐ ‐ 19 ‐ ‐ 19 ‐ BitRMS 5 Data Update Rate fUPDATE 108 111 114 108 111 114 108 111 114 Hz 6 1) Percentage of selected range. 2) Uncertainty limited by system noise for ranges of 0.5 inH2O and below. 3) Includes errors of offset, span and thermal effects. 4) Each selected range has the specified resolution 5) ENOB stated for fBW set to 0.1 Hz. 6) The internal update rate is fixed and does not change with range or filter settings. Sampling at lower data rates are possible provided the Nyquist frequency is observed. It is suggested to sample at least 3x the set fBW frequency. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |