7 / 27 page ![]() 7 Common Sockets Specifications Socket Characteristics * The insulation resistance was measured with a 500-VDC insulation resistance meter at the same places as those used for measuring the dielectric strength. Safety Precautions Refer to Common Relay Precautions for general precautions. Model Continuous carry current Dielectric strength Insulation resistance* Remarks P2RFZ-05-E 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 4,000 VAC for 1 min P2RFZ-08-E 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2RF-05(-E) 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 4,000 VAC for 1 min P2RF-08(-E) 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2R-05P 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 4,000 VAC for 1 min P2R-08P 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2R-057P 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between coil and contact terminals: 5,000 VAC for 1 min P2R-087P 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between coil and contact terminals: 5,000 VAC for 1 min P2R-05A 10 A Between contact terminals of same polarity: 1,000 VAC for 1 min 1,000 M Ω min. Between ground terminals: 1,500 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P2R-08A 5 A Between contact terminals of different polarity: 3,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 1,000 VAC for 1 min Between ground terminals: 1,500 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min P7TF-05 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYFZ-08(-E) 10 A Between contact terminals of different polarity: 2,250 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 2,250 VAC for 1 min Between coil and contact terminals: 2,250 VAC for 1 min PYF08A(-E) 7 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. The continuous carry current of 10 A for the PYF08S is for an ambient temperature of 55°C. At an ambient temperature of 70°C, the value is 7 A. PYF11A 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PYFZ-14(-E) 6 A Between contact terminals of different polarity: 2,250 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 2,250 VAC for 1 min Between coil and contact terminals: 2,250 VAC for 1 min PYF14A(-E) 3 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PY08(-Y1)(-Y3) 7 A Between terminals: 1,500 VAC for 1 min 1,000 M Ω min. PY08QN(-Y1) 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY08-02 7 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11QN(-Y1) 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY11-02 5 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14(-Y1)(-Y3) 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14QN(-Y1) 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PY14-02 3 A Between terminals: 1,500 VAC for 1 min 100 M Ω min. PTF @@A(-E) 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT @@ 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT @@QN 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. PT @@-0 10 A Between terminals: 2,000 VAC for 1 min 100 M Ω min. P7LF-06 30 A Between contact terminals of different polarity: 2,000 VAC for 1 min 1,000 M Ω min. Between contact terminals of same polarity: 2,000 VAC for 1 min Between coil and contact terminals: 4,000 VAC for 1 min PF @@@A(-E) 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P2CF- @(-E) 5 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. 8PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. 11PFA(1) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. P3G(A)- @ 6 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PL @(-Q) 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. PLE @@-0 10 A Between terminals: 2,000 VAC for 1 min 1,000 M Ω min. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |