Back Button AS3689 Datasheet HTML 55Page - ams-OSRAM AG AS3689 Datasheet HTML 56Page - ams-OSRAM AG AS3689 Datasheet HTML 57Page - ams-OSRAM AG AS3689 Datasheet HTML 58Page - ams-OSRAM AG AS3689 Datasheet HTML 59Page - ams-OSRAM AG AS3689 Datasheet HTML 60Page - ams-OSRAM AG AS3689 Datasheet HTML 61Page - ams-OSRAM AG AS3689 Datasheet HTML 62Page - ams-OSRAM AG AS3689 Datasheet HTML 63Page - ams-OSRAM AG Next Button
Zoom Inzoom in Zoom Outzoom out
 59 / 72 page
background image
AS3689
austriami crosyst ems
Datasheet, Confidential
www.austriamicrosystems.com (mlg, ptr)
Revision 1.0.2 / 20070115
57 - 70
Table 26 – Serial Data Transfer Byte Definitions
Symbol
Definition
R/W (AS3689 Slave)
Notes
S
Start Condition after Stop
R
1 bit
Sr
Repeated Start
R
1 bit
DW
Device Address for Write
R
10000010b (80h).
DR
Device Address for Read
R
10000011b (81h)
WA
Word Address
R
8 bits
A
Acknowledge
W
1 bit
N
Not Acknowledge
R
1 bit
reg_data
Register Data/Write
R
8 bits
data (n)
Register Data/read
R
1 bit
P
Stop Condition
R
8 bits
WA++
Increment Word Address Internally
R
During Acknowledge
Figure 33 – Serial Interface Byte Write
S
DW
A
WA
A
reg_data
A P
Write Register
WA++
AS3689 (= Slave) receives data
AS3689 (= Slave) transmits data
Figure 34 – Serial Interface Page Write
S
DW
A
WA
A
reg_data 1
A
reg_data 2
A
reg_data n
A P
Write Register
WA++
Write Register
WA++
Write Register
WA++
AS3689 (= Slave) receives data
AS3689 (= Slave) transmits data
Byte Write and Page Write formats are used to write data to the slave.
The transmission begins with the START condition, which is generated by the master when the bus is in IDLE
state (the bus is free). The device-write address is followed by the word address. After the word address any
number of data bytes can be sent to the slave. The word address is incremented internally, in order to write
subsequent data bytes on subsequent address locations.
For reading data from the slave device, the master has to change the transfer direction. This can be done either
with a repeated START condition followed by the device-read address, or simply with a new transmission START
followed by the device-read address, when the bus is in IDLE state. The device-read address is always followed
by the 1st register byte transmitted from the slave. In Read Mode any number of subsequent register bytes can
be read from the slave. The word address is incremented internally.
The following diagrams show the serial read formats supported by the AS3689.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com