| Electronic Components Datasheet Search |
|
AS3689 Datasheet(PDF) 60 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3689 Datasheet(HTML) 60 Page - ams-OSRAM AG |
|
60 / 72 page ![]() AS3689 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (mlg, ptr) Revision 1.0.2 / 20070115 58 - 70 Figure 35 – Serial Interface Random Read S DW A WA A Sr DR A data N P Read Register WA++ AS3689 (= slave) receives data AS3689 (= slave) transmits data Random Read and Sequential Read are combined formats. The repeated START condition is used to change the direction after the data transfer from the master. The word address transfer is initiated with a START condition issued by the master while the bus is idle. The START condition is followed by the device-write address and the word address. In order to change the data direction a repeated START condition is issued on the 1st CLK pulse after the ACKNOWLEDGE bit of the word address transfer. After the reception of the device-read address, the slave becomes the transmitter. In this state the slave transmits register data located by the previous received word address vector. The master responds to the data byte with a NOT ACKNOWLEDGE, and issues a STOP condition on the bus. Figure 36 – Serial Interface Sequential Read S DW A WA A Sr DR A data 1 A data 2 AS3689 (= slave) receives data AS3689 (= slave) transmits data ... A data n N P Read Register WA++ Sequential Read is the extended form of Random Read, as multiple register-data bytes are subsequently transferred. In contrast to the Random Read, in a sequential read the transferred register-data bytes are responded by an acknowledge from the master. The number of data bytes transferred in one sequence is unlimited (consider the behavior of the word-address counter). To terminate the transmission the master has to send a NOT ACKNOWLEDGE following the last data byte and subsequently generate the STOP condition. Figure 37 – Serial Interface Current Address Read S DR A data 1 A data 2 … A data n N P Read Register WA++ Read Register WA++ Read Register WA++ Read Register WA++ AS3689 (= slave) receives data AS3689 (= slave) transmits data To keep the access time as small as possible, this format allows a read access without the word address transfer in advance to the data transfer. The bus is idle and the master issues a START condition followed by the Device- Read address. Analogous to Random Read, a single byte transfer is terminated with a NOT ACKNOWLEDGE after the 1st register byte. Analogous to Sequential Read an unlimited number of data bytes can be transferred, where the data bytes must be responded to with an ACKNOWLEDGE from the master. For termination of the transmission the master sends a NOT ACKNOWLEDGE following the last data byte and a subsequent STOP condition. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |