| Electronic Components Datasheet Search |
|
CS-LDTC05 Datasheet(PDF) 4 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
CS-LDTC05 Datasheet(HTML) 4 Page - Wavelength Electronics, Inc. |
|
4 / 4 page ![]() Case Study CS-LDTC05 Rev. A Page 4 © 2019 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com KEYWORDS optofluidic, microfluidic, cell sorting, PCR, laser control, temperature control, optical tweezers, water absorption PRODUCTS USED PLD5K-CH, LDTC2/2 REVISION HISTORY Document Number: CS-LDTC05 REVISION DATE NOTES A April 2019 Initial Release REFERENCES 1. J.R. Kovac and J. Voldman, "Intuitive, Image-Based Cell Sorting Using Optofluidic Cell Sorting," Anal. Chem. 79(24), 9321-9330 (2007). 2. D.C. Saunders, G.L. Hols, C.R. Phaneuf, N. Pak, M. Marchese, N. Sondej, M. McKinnon, C.R. Forest, "Rapid, quantitative, reverse transcription PCR in a polymer microfluidic chip," Biosensors and Bioelectronics 44, 222-228 (2013). USEFUL LINKS • PLD5K-CH Product Page • LDTC2/2 Product Page LASER DIODE CONTROL SOLUTIONS In both instances described here, infrared wavelength was chosen for the way it interacts with the media in the respective experiments. Additionally, the absorption spectra of water varies drastically in the infrared, and the researchers used that to their advantage. In both cases, the laser power delivered to the microchip was a crucial experimental parameter. In [1], the power needed to be well-controlled to ensure the viability of the cells being removed. In [2], the delivered power directly impacts the results of the PCR, since PCR requires specific temperatures for each phase. In each case, the laser driver plays a role in the quality of the output. Wavelength's LDTC2/2 utilizes the WLD3343 laser driver, which has 200 ppm stability, and was used to drive the cell-removal laser. The PLD5K-CH drove the infrared laser used to thermal cycle the PCR microchip. The PLD has <100 ppm stability, allowing precision power output of the infrared laser. For the cell-removal experiment, the WTC3243 is used for temperature control. The WTC allows for temperature control on the order of 0.009°C. This stability minimized wavelength fluctuations. This data is summarized below, in Table 1. EXPERIMENT CONTROLLER STABILITY Cell Removal LDTC2/2 200 ppm (laser) 0.009°C (temperature) PCR PLD5K-CH <100 ppm Table 1. Stability specifications for the controllers used in the described experiments. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |