Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

CS-LDTC17 Datasheet(PDF) 3 Page - Wavelength Electronics, Inc.

Part # CS-LDTC17
Description  Scalable Modular Tomography Sensor for High-Speed Gas-Turbine Exhaust Imaging
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  WAVELENGTH [Wavelength Electronics, Inc.]
Direct Link  https://www.teamwavelength.com/
Logo WAVELENGTH - Wavelength Electronics, Inc.

CS-LDTC17 Datasheet(HTML) 3 Page - Wavelength Electronics, Inc.

  CS-LDTC17 Datasheet HTML 1Page - Wavelength Electronics, Inc. CS-LDTC17 Datasheet HTML 2Page - Wavelength Electronics, Inc. CS-LDTC17 Datasheet HTML 3Page - Wavelength Electronics, Inc. CS-LDTC17 Datasheet HTML 4Page - Wavelength Electronics, Inc. CS-LDTC17 Datasheet HTML 5Page - Wavelength Electronics, Inc.  
Zoom Inzoom in Zoom Outzoom out
 3 / 5 page
background image
Case Study CS-LDTC17 Rev. A
Page 3
© 2026 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com
For on-site testing on the APU exhaust plume (
Figure 5),
the region of interest (ROI) was one of the main parameters
that changed with the scalable and modular CST design.
The ROI was set with a side length of 310 mm to cover the
full extent of the plume. With the ROI meshed into 50 x 50
grid cells, the spatial resolution in this ROI is 8.1 mm.1
Figure 5. On-site CST system setup on imaging the
APU exhaust plume with beams from two projection
angles (out of the four angles, due to the limited intensity
of the red laser) is shown in ROI visualization.1
RESULTS
The system's efficacy was first validated through lab-scale
experiments on propane/air flames and subsequently
deployed on a commercial Honeywell 131-9 A APU.
The results demonstrated significant advancements in
diagnostic precision.
Researchers first reconstructed water vapor concentration
and temperature distributions in post-combustion fields with
lab-scale burners (annular and triple flame). With the central
ROI reduced to 160 x 160 mm2, imaging of the temperature
and concentration of water vapor is determined.
Figure 6
shows the reconstructions of both the annular and triple
flame setups. For a reconstructed annular flame, the
system measured a peak temperature of 1127.4 K and
a peak concentration of 0.059. In triple-flame tests, the
sensor accurately localized three distinct hot spots with
peak temperatures and concentrations of 1264 K and
0.041, 1141 K and 0.036, and 1279 K and 0.038.1
Figure 6. One-second averaged reconstructions of (a)
temperature and (b) H
2O concentration of the annular
flame, and (c) temperature and (d) H
2O concentration of
the triple flame.1
The reconstructed flames show strong agreement with the
expected flame features, specifically the flame positions,
geometric dimensions, and non-uniformity. The measured
distance between the triple-flame sub-centers was
54.9 mm, deviating by only 1.5 mm from the actual 56.4 mm
layout, confirming the sensor's spatial accuracy. The spatial
distribution also gives insight into the internal structure and
symmetry of the flames.1
At 250 fps, the sensor captured a dominant fluctuation
frequency of 9 Hz in the annular flame, likely caused by
periodic vortex shedding,1 a feature that slower systems
would miss entirely. With the reconstructions successfully
performed, the CST sensor was further validated through
the on-site APU experiment.
As thermal expansion can lead to 20-30 mm extension
of the experiment exhaust tube, the CST imaging plane
was chosen 45 mm downstream from the exit. With only
three minutes of test runtime, the sensor successfully
reconstructed 2D fields across a 310 mm ROI. There was
minimal noise added to the system due to mechanical
vibrations because of the well-aligned laser beams. The
wavelength modulation spectroscopy (WMS) based
CST system provided raw laser transmission of one
representation beam across four consecutive scans in 4 ms
(
Figure 7a) as well as demodulated 2ƒ/1 ƒ signals at the
corresponding water vapor absorption feature transitions
(
Figure 7b & c). Figure 8 shows the reconstruction of the
distributions of temperature and water vapor concentrations
of the gas turbine. The reconstructions clearly revealed non-
uniform gas-state distributions in the APU's exhaust plume,
proving the system's readiness for industrial environments.



Html Pages

1 2 3 4 5


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com