| Electronic Components Datasheet Search |
|
3RW301. Datasheet(PDF) 13 Page - Siemens Semiconductor Group |
|
|
|||||||||||||||||||||||||||||
3RW301. Datasheet(HTML) 13 Page - Siemens Semiconductor Group |
|
13 / 40 page ![]() How is the SIRIUS 3RW40 set? Like with the SIRIUS 3RW30, the starting voltage, ramp-up and ramp-down time of the voltage ramp, as well as the current limiting, can be comfortably set via finely adjustable rotary potentiometers. The nominal motor current, tripclass and reset of the motor overload function are adjusted via potentiometers and buttons, as is familiar from the SIRIUS overload relays. What are its outstanding characteristics? The SIRIUS 3RW40 comes with the new patented control principle “polarity balancing” for the avoidance of DC components in two-phase-controlled soft starters. With two-phase-controlled soft starters, the current resulting from the overlapping of the two controlled phases flows in the uncontrolled phase. For physical reasons, this results in an asymmetric distribution of the three phase currents during the motor’s start- up process. Even though this distribution cannot be influenced, it is uncritical in most applications. However, besides this asymmetry, the power semiconductors’ control during the two controlled phases also produces the above-mentioned DC components, which may lead to a loud motor noise with starting voltages lower than 50%. “Polarity balancing” reliably eliminates these DC components during the start-up phase. It generates an even motor start-up in terms of speed, torque and current rise. The acoustic quality of the start-up process almost reaches the quality of a three-phase-controlled start-up. This is made possible by the continuous dynamic alignment and Is thermistor motor protection available Device versions with thermistor motor protection evaluation are available up to a rating of 55 kW (with 400 V). A “Thermoclick” measuring sensor or PTC (type A) can be directly connected. In addition to thermal motor overload, wire breakage and short circuit in the sensor circuit effect a disconnection of the soft starter. What about reset options? After the soft starter has tripped, various reset options are available, like for intrinsic device and motor overload protection: manual or via the reset button, automatic or (up to 55 kW) remotely via short-term control voltage interruption. Is replacement easy? Yes, also the 3RW40 is equipped with removable control terminals. The wiring on the terminal thus remains intact (“permanent wiring”) in case of replacement and the terminals are simply snapped onto the new 3RW40, which saves a considerable amount of time. How about accessories? We offer a comprehensive range of accessories for our soft starters, e.g. box terminal blocks, accessories for mechanical reset and a module for remote reset (for ratings > 75 kW) as well as a sealing cover and easy-to-mount terminal covers for optimum touch protection. Furthermore, snap-on fans are available for the devices up to 55 kW which facilitate mounting of the SIRIUS 3RW40 in almost any installation position and support higher switching duties. In addition, connection modules for electrical and mechanical connections between circuit breaker and soft starter as well as labeling strips from the SIRIUS range are available. balancing of current half-waves with different polarity during the motor start-up. Does the SIRIUS 3RW40 feature additional protective functions? The SIRIUS 3RW40 is equipped with optimum functionality as standard. An integrated bypass contact system reduces the soft starter’s heat loss during operation. This reliably prevents heating of the switching device‘s environment. The integrated motor overload protection in accordance with IEC 60 947-4-2 makes an additional overload relay unnecessary, to save space in the control cabinet and reduce the wiring costs in the feeder. The overload tripclass can be variably set via a 4-level rotary potentiometer. In addition, intrinsic device protection prevents the thyristors’ thermally overloading and resulting defects of the power components. Optionally, the thyristors can also be protected against short circuit with SITOR semiconductor fuses. Also inrush current peaks are reliably eliminated, thanks to settable current limiting. Does the SIRIUS 3RW40 offer diagnostics options? Yes, thanks to integrated status and fault monitoring. LEDs provide information on the operating state as well as possible faults, e.g. impermissible release time (CLASS setting), mains or phase failure, missing load, thermal overload or device fault. The two integrated output relays also indicate the operating state and fault signals. 13 © Siemens AG 2008 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |