| Electronic Components Datasheet Search |
|
E32-R16 5M Datasheet(PDF) 9 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E32-R16 5M Datasheet(HTML) 9 Page - Omron Electronics LLC |
|
9 / 13 page ![]() 9 E3X-HD Safety Precautions Refer to the Fiber Sensors Technical Guide for precautions that apply to all Fiber Sensors. • Be sure to mount the unit to the DIN track until it clicks. • Use an extension cable with a minimum thickness of 0.3 mm2 and less than 100 m long. • Do not subject the cable to more than the following forces. Pull: 40 N; torque: 0.1 N ⋅m; pressure: 20 N; bending: 29.4 N • The Sensor is ready to operate 200 ms after the power supply is turned ON. • When using Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with E3X-CN-series Connectors) on the unused power pins to prevent electrical shock and short circuiting. When using Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with E3X-CRT/ECT Sensor Communications Unit). • Output pulses may occur when the power supply is turned OFF. Turn OFF the power supply to the load or load line first. • Excessive incident light cannot be sufficiently handled by the mutual interference prevention function and may cause malfunction. To prevent this, set a higher threshold level. • Make sure that the power supply is turned OFF before connecting, separating, or adding Amplifier Units. • Do not pull on or apply excessive pressure or force to the Fiber Unit when it is attached to the Amplifier Unit. • The E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S Mobile Consoles cannot be used. • Mutual interference prevention on the E3X-HD Series does not function among the E3NX-FA, E3X-DA-N, E3X-SD, or E3X-NA Fiber Amplifier Units. Mutual interference prevention on the E3X-HD Series does function among the E3X-DA-S and E3X-MDA Fiber Amplifier Units. • The E3X-CRT and E3X-ECT Sensor Communications Unit can be used with the E3X-HD0, but the E3X-DRT21-S and E3NW-ECT Sensor Communications Units cannot be used. • Always keep the protective cover in place when using the Amplifier Unit. • Do not use thinner, benzine, acetone, and kerosene for cleaning. For technical information and product FAQs, refer to the Technical Guide on your OMRON website. Warning This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with AC power supply. Otherwise, explosion may result. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the product. Doing so may cause damage or fire. 1. Do not install the product in the following locations. • Locations subject to direct sunlight • Locations subject to condensation due to high humidity • Locations subject to corrosive gas • Locations subject to vibration or mechanical shocks exceeding the rated values • Locations subject to exposure to water, oil, chemicals • Locations subject to stream • Locations subjected to strong magnetic field or electric field 2. Do not use the product in environments subject to flammable or explosive gases. 3. To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. 4. High-Voltage lines and power lines must be wired separately from this product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. 5. Do not apply load exceeding the ratings. Otherwise, damage or fire may result. 6. Do not short the load. Otherwise, damage or fire may result. 7. Connect the load correctly. 8. Do not miswire such as the polarity of the power supply. 9. Do not use the product if the case is damaged. 10. Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning. 11. When setting the Sensor, be sure to check safety, such as by stopping the equipment. 12. Be sure to turn off the power supply before connecting or disconnecting wires. 13. Do not attempt to disassemble, repair, or modify the product Unit in any way. 14. When disposing of the product, treat it as industrial waste. 15. Do not use the Sensor in water, rainfall, or outdoors. Precautions for Correct Use Protective Sticker Power Supply Connecting Terminal Protective Cap Amplifier Unit with Wire-saving Connector Amplifier Unit with Connector for Communications Unit |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |