| Electronic Components Datasheet Search |
|
AV4504 Datasheet(PDF) 11 Page - Panasonic Semiconductor |
|
|
|||||||||||||||||||||||||||||
AV4504 Datasheet(HTML) 11 Page - Panasonic Semiconductor |
|
11 / 16 page ![]() Panasonic Corporation Electromechanical Control Business Division industrial.panasonic.com/ac/e/ Technical Terminology & Cautions for Use (Detection Switches) Panasonic Corporation 2021 AECTB36E 202110 TECHNICAL NOTES ON MECHANICAL CHARACTERISTICS Actuation Force and Stroke Adequate stroke setting is the key to high reliability. It is also important that adequate contact force be ’maintained to ensure high reliability. For a normally closed (N.C.) circuit, the driving mechanism should be set so that the actuator is normally in the free position. For a normally open (N.O.) circuit, the actuator should be pressed to 70% to 100% of the specified stroke to absorb possible errors. If the stroke is set too close to the operating point (OP), this may cause unstable contact, and in the worst case may cause actuator damage due to inertia of the drive mechanism. It is advisable that the stroke be adjusted with the mounting plate or driving mechanism. The figure at right shows a typical example of activation and contact forces varying with stroke. In the vicinity of the OP and RP, the contact force is diminished, causing chatter and contact bounce immediately before or after reversal. For this reason, use the switch while giving due consideration to this. This also causes the snap action switch to be sensitive to vibration or shock. OF RF PT N.C. On FP On reversal On reversal On OTP N.O. Stroke MD OT FP RP OP TTP Stroke Changes in Operating Characteristics Exercise design care so that malfunctions will not occur if the operating characteristics vary by as much as 20% from, rated values. <Example> In the OF Max. 0.98N specification for FS snap-action switches, the allowable Max. is 0.98 N (100%+20%) = 1.18 N In the RF Min. 0.15 N Min. specification the allowable Min. 0.15 N (100%–20%) = 0.12 N Mechanical Conditions for Type Selection Actuator type should be selected according to activation method, activation speed, activation rate, and activation frequency. 1) An extremely slow activation speed may cause unstable contact transfer, possibly resulting in contact failures or contact fusion. 2) An extremely high activation speed may cause damage to contacts or contact response failure. Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided. <Example> Bad Good TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1) The snap-action switch is designed for AC operations. While it has small contact gaps and no arc absorber, it may be used for low- capacity DC operations. Please refer to the rating of each products 2) For applications with very small switching voltage or current, choose the low-level load type (Au contact). Small current and voltage application range (Au contact) 500 100 50 5 2 1 4 8 12 16 20 24 10 DC voltage (VDC) 3) When selecting a contact type of a snap-action switch to be used for low-level load switching, the following should be noted. Silver contacts’ surfaces are prone to be oxidized and form a sulfide film. The switch operates with no problems at thebeginning of use. However, as the contact surfaces develop films with time, the film may not be broken by the switching operation, causing a conduction failure. Therefore, please choose the Au contact type for switching a load of 0.1 A or below. 4) Application to Electronic Circuits • The snap-action switch contacts can sustain bounce or chatter when closed. Bounce or chatter can cause noise or pulse count errors when the snap action switch is used in electronic circuits. • If contact bounce or chatter poses problems in the vicinity of the OP and RP, use a suitable absorption network, such as a C/ R network. 5) Check the surge current, normal current and surge duration. 6) Contact resistance given in performance specifications is measured with a voltage drop method using 6 to 8 V DC, 1 A (except for low-level load type). Contact resistance across COM and N.C. terminals is measured in the free position, while contact resistance across COM and N.O. terminals is measured in the total travel position. 7) To prevent contact welding failure, be sure to use a serial resistance for each capacitive load. 8) If snap-action switch operation is synchronized with the AC supply phase, this may cause: shortened electrical life, contact fusion failure, contact transfer, or other reliability problems. ー 11 ー |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |