Back Button HD404369F Datasheet HTML 24Page - Renesas Technology Corp HD404369F Datasheet HTML 25Page - Renesas Technology Corp HD404369F Datasheet HTML 26Page - Renesas Technology Corp HD404369F Datasheet HTML 27Page - Renesas Technology Corp HD404369F Datasheet HTML 28Page - Renesas Technology Corp HD404369F Datasheet HTML 29Page - Renesas Technology Corp HD404369F Datasheet HTML 30Page - Renesas Technology Corp HD404369F Datasheet HTML 31Page - Renesas Technology Corp HD404369F Datasheet HTML 32Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 117 page
background image
HD404369 Series
26
Operating Modes
The MCU has five operating modes as shown in table 17. The operations in each mode are listed in tables
18 and 19. Transitions between operating modes are shown in figure 11.
Active Mode: All MCU functions operate according to the clock generated by the system oscillator OSC
1
and OSC
2.
Table 17
Operating Modes and Clock Status
Mode Name
Active
Standby
Stop
Watch
Subactive*
2
Activation method
RESET cancellation,
interrupt
STOPC
cancellation in stop
mode, STOP/SBY
instruction in
subactive mode
(when direct transfer
is selected)
SBY
instruction
STOP
instruction when
TMA3 = 0
STOP
instruction when
TMA3 = 1
INT
0 or timer A
interrupt request
from watch
mode
Status System
oscillator
OP
OP
Stopped
Stopped
Stopped
Subsystem
oscillator
OP
OP
*
1 OP
OP
OP
Cancellation
method
RESET input,
STOP/SBY instruction
RESET
input,
interrupt
request
RESET input,
STOPC input in
stop mode
RESET input,
INT
0 or timer A
interrupt request
RESET input,
STOP/SBY
instruction
Notes: OP implies in operation
1. Operating or stopping the oscillator can be selected by setting bit 3 of the system clock select
register 1 (SSR1: $027).
2. Subactive mode is an optional function; specify it on the function option list.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com