| Electronic Components Datasheet Search |
|
HAL880 Datasheet(PDF) 11 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
HAL880 Datasheet(HTML) 11 Page - Micronas |
|
11 / 34 page ![]() DATA SHEET HAL880 Micronas Feb. 23, 2009; DSH000152_001EN 11 2.3. Calibration Procedure 2.3.1. General Procedure For calibration in the system environment, the applica- tion kit from Micronas is recommended. It contains the hardware for the generation of the serial telegram for programming (Programmer Board Version 5.1) and the corresponding software (PC880) for the input of the register values. For the individual calibration of each sensor in the cus- tomer application, a two-point adjustment is recom- mended. The calibration has be done as follows: Step 1: Input of the registers which need not be adjusted individually The magnetic circuit, the magnetic material with its temperature characteristics, the filter frequency, the output mode and the GP register value are given for this application. Therefore, the values of the following registers should be identical for all sensors of the customer application. –FILTER (according to the maximum signal frequency) –RANGE (according to the maximum magnetic field at the sensor position) –OUTPUTMODE – TC, TCSQ, and TC-RANGE (depends on the material of the magnet and the other temperature dependencies of the application) –GP (if the customer wants to store own production infor- mation, it is not necessary to change this register) As the clamping voltages are given, they have an influ- ence on the D/A-readout value and therefore have to be set after the adjustment process. Write the appropriate settings into the HAL880 registers. Step 2: Initialize DSP As the D/A-READOUT register value depends on the settings of SENSITIVITY, VOQ, and CLAMP-LOW/HIGH, these registers have first to be initialized with defined values: –VOQINITIAL = 2.5 V – SensitivityINITIAL = 0.5 –Clamp-Low = 0 V – Clamp-High = 4.999 V Step 3: Define Calibration Points The calibration points 1 and 2 can be set inside the specified range. The corresponding values for VOUT1 and VOUT2 result from the application requirements. For highest accuracy of the sensor, calibration points near the minimum and maximum input signal are recommended. The difference of the output voltage between calibration point 1 and calibration point 2 should be more than 3.5 V. Step 4: Calculation of VOQ and Sensitivity Set the system to calibration point 1 and read the reg- ister D/A-READOUT. The result is the value D/A-READOUT1. Now, set the system to calibration point 2, read the register D/A-READOUT again, and get the value D/A-READOUT2. With these values, and the target values VOUT1 and VOUT2, for the calibration points 1 and 2, respectively, the values for Sensitivity and VOQ are calculated as: This calculation has to be done individually for each sensor. Next, write the calculated values for Sensitivity and VOQ into the IC for adjusting the sensor. At that time, it is also possible to store the application specific values for Clamp-Low and Clamp-High into the sensors EEPROM. Lowclampingvoltage V OUT1,2 Highclampingvoltage ≤≤ Sensitivity 1 2 --- Vout2 Vout1 – () D/A-Readout2 D/A-Readout1 – ----------------------------------------------------------------------------------- × 16384 5 --------------- × = V OQ 1 16 ------ Vout2 16384 × 5 ------------------------------------- D/A-Readout28192 – () Sensitivity × 2 × [] – × 5 1024 ------------ × = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |