| Electronic Components Datasheet Search |
|
HAL880 Datasheet(PDF) 12 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
HAL880 Datasheet(HTML) 12 Page - Micronas |
|
12 / 34 page ![]() HAL880 DATA SHEET 12 Feb. 23, 2009; DSH000152_001EN Micronas The sensor is now calibrated for the customer applica- tion. However, the programming can be changed again and again if necessary. Note: For a recalibration, the calibration procedure has to be started at the beginning (step 1). A new initialization is necessary, as the initial values from step 1 are overwritten in step 4. Step 5: Locking the Sensor The last step is activating the LOCK function by pro- gramming the LOCK bit. Please note that the LOCK function becomes effective after power-down and power-up of the Hall IC. The sensor is now locked and does not respond to any programming or reading com- mands. Warning: This register can not be reset! |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|