| Electronic Components Datasheet Search |
|
705-5202-21 Datasheet(PDF) 10 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
705-5202-21 Datasheet(HTML) 10 Page - Magnetrol International, Inc. |
|
10 / 28 page ![]() Measuring range: min 12" (30 cm) max 224" (570 cm) E Probe Insertion Length = + measuring range + F E 20 mA / 100 % 4 mA / 0 % min 1" (25 mm) Body connection F P Before After Manufacturer Type Process connection Displacer length inches (mm) Probe length inches (mm) Magnetrol® EZ & PN Modulevel® ANSI/DIN flange ≥ 14" (356) Displacer + 7 (178) Masoneilan® Series 1200 Proprietary flange ≥ 14" (356) Displacer + 8 (203) ANSI/DIN flange ≥ 16" (406) Displacer + 8 (203) Fisher® series 2300 & 2500 249B, 259B, 249C cages Proprietary flange ≥ 14" (356) Displacer + 10 (254) other cages ANSI flange ≥ 14" (356) consult factory Eckhardt® Series 134, 144 ANSI/DIN flange ≥ 14" (356) consult factory Tokyo Keiso® FST-3000 ANSI/DIN flange H = 11.8" (300) Displacer + 9 (229) ANSI/DIN flange ≥ H = 19.7" (500) Displacer + 9 (229) Recomended probe length for replacing displacer transmitters The table below helps to define the GWR probe length for the most common displacer transmitters. Refer to the flange selection guide on the next page. Round down resulting calculation to the nearest inch. Eclipse has proven to be the ideal replacement for exist- ing torque tube transmitters. In numerous applications around the world, customers have found Eclipse Guided Wave Radar superior to torque tube transmitters: • Cost: A new Eclipse costs only slightly more than rebuilding an aging torque tube. • Installation: No field calibration is necessary; it can be configured in minutes with no level movement. Factory pre-con- figuration is available. • Performance: Eclipse is not affected by changes in specific gravity or dielectric. • Ease of replacement: Proprietary flanges are offered so existing chamber/ cages can be used. In order to match the proper Eclipse transmitter with the proper external cage, consider the following: • Type of application: Use the applicable GWR probe, see pages 16 to 27. • Overfill proof: “Overfill” occurs when the level rises above the maxi- mum range of operation. Radar based probes may pro- vide erroneous output in this zone unless an optimal design is used. Eclipse GWR overfill probes without top transition zones (e.g., 7xG, 7xR, 7xD, 7xT) are always safe to use. In cases where the application demands a different probe type, other selections can be considered and the recommended installation pre- cautions should be followed. • Min cage size: • Coaxial type: min 2" • Enlarged Coaxial Type: min 3" • Twin rod type: min 3" • Caged GWR type: 2" R E P L A C E M E N T O F D I S P L A C E R T R A N S M I T T E R 10 H Displacer Length |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |