| Electronic Components Datasheet Search |
|
MMA7660FC Datasheet(PDF) 21 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MMA7660FC Datasheet(HTML) 21 Page - Freescale Semiconductor, Inc |
|
21 / 35 page ![]() Sensors 21 Freescale Semiconductor, Inc. MMA7660FC $09: Tap/Pulse Detection Register (Read/Write) PDET NOTE: If XDA = YDA = ZDA = 0, samples per second is 120 samples/second, and Auto-Wake/Sleep feature is enabled, the tap interrupt will reset the sleep counter. XDA 1: X-axis is disabled for tap detection 0: X-axis is enabled for tap detection YDA 1: Y-axis is disabled for tap detection 0: Y-axis is enabled for tap detection ZDA 1: Z-axis is disabled for tap detection 0: Z-axis is enabled for tap detection $0A: PD: Tap/Pulse Debounce Count Register (Read/Write) D7 D6 D5 D4 D3 D2 D1 D0 ZDA YDA XDA PDTH[4] PDTH[3] PDTH[2] PDTH[1] PDTH[0] 0 0 0 000 00 PDTH[4:0] DESCRIPTION 00000 Tap detection threshold is ±1 count 00001 00010 Tap detection threshold is ±2 counts 00011 Tap detection threshold is ±3 counts ... ... and so on up to... 11101 Tap detection threshold is ±29 counts 11110 Tap detection threshold is ±30 counts 11111 Tap detection threshold is ±31 counts D7 D6 D5 D4 D3 D2 D1 D0 PD[7] PD[6] PD[5] PD[4] PD[3] PD[2] PD[1] PD[0] 0 000000 0 PD[4:0] DESCRIPTION 00000000 The tap detection debounce filtering requires 2 adjacent tap detection tests to be the same to trigger a tap event and set the Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection response time is nominally 0.52 ms. 00000001 00000010 Tap detection debounce filtering requires 3 adjacent tap detection tests to be the same to trigger a tap event and set the Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection response time is nominally 0.78 ms. 00000011 Tap detection debounce filtering requires 4 adjacent tap detection tests to be the same to trigger a tap event and set the Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection response time is nominally 1.04 ms. ... ... and so on up to... 11111101 Tap detection debounce filtering requires 254 adjacent tap detection tests to be the same to trigger a tap event and set the Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection response time is nominally 66.04 ms. 11111110 Tap detection debounce filtering requires 255 adjacent tap detection tests to be the same to trigger a tap event and set the Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection response time is nominally 66.3 ms. 11111111 Tap detection debounce filtering requires 256 adjacent tap detection tests to be the same to trigger a tap event and set the Tap bit in the TILT (0x03) register, and optionally set an interrupt if PDINT is set in the INTSU (0x06) register. Tap detection response time is nominally 66.56 ms. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |