| Electronic Components Datasheet Search |
|
AS3665 Datasheet(PDF) 32 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3665 Datasheet(HTML) 32 Page - ams AG |
|
32 / 78 page ![]() www.austriamicrosystems.com Revision 1.0.2 31 - 77 AS3665 Datasheet, Confidential - D e ta i l e d D e s c r i p t i o n C h a r g e P u m p The charge pump starts operation always in 1:1 mode and returns back to 1:1 mode if all current sources are switched off 7. If the voltage across a enabled current source is no longer sufficient to operate the current source, the charge pump automatically select the next operating mode (which modes are allowed is controlled by cp_mode_switching. cp_auto_on or cp_on should be set for enabling this logic). In 1:1.5 mode and if cp_mode_switching=00, the charge pump also can automatically switch back into 1:1 mode if the voltage across all current sources is sufficiently high to use the more efficient 1:1 mode (a fine adjustment of this hysteresis is possible with cp_down_hyst). Application Hint Its usually safe to keep the default values of the charge pump registers. Only if a red LED is used (on LED7...LED9), reset the register bits LED7_on_cp=0, LED8_on_cp=0 and/or LED9_on_cp=0 to improve efficiency. 7. Exception: The manual mode switching mode (cp_mode_switching=11) can override this behavior. Table 38. CP_Mode_Switch Register Addr: 06h CP_Mode_Switch Register Bit Bit Name Default Access Description 0 LED7_on_cp 1b R/W Configure if LED7 is powered by charge pump 0 LED7 is powered by VBAT (e.g. red LED) 1 LED7 is powered from VOUT 1 LED8_on_cp 1b R/W Configure if LED8 is powered by charge pump 0 LED8 is powered by VBAT (e.g. red LED) 1 LED8 is powered from VOUT 2 LED9_on_cp 1b R/W Configure if LED9 is powered by charge pump 0 LED9 is powered by VBAT (e.g. red LED) 1 LED9 is powered from VOUT 3 cp_max_5V4 0b R/W Adjusts the maximum output voltage of the charge pump 0 charge pump VOUT regulates to 4.5V 1 charge pump VOUT regulates to maximum 5.4V 4 cp_skip_on 1b R/W Allows pulse skip mode of charge pump 0 Pulse skip of charge pump is disabled 1 Enable pulse skip of charge pump in low load conditions (reduce quiescent current in 1:1.5 mode) 5 cp_auto_reset 1b R/W If all current sources are off, reset the charge pump back to 1:1 mode 0 charge pump keeps last mode 1 Reset charge pump to 1:1 if all current sources are off |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |