| Electronic Components Datasheet Search |
|
AS3668 Datasheet(PDF) 16 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3668 Datasheet(HTML) 16 Page - ams AG |
|
16 / 59 page ![]() www.ams.com/AS3668 Revision 1.13 16 - 59 AS3668 Data Sheet - Detailed Description 8.1.4 Charge Pump Control Register . 8.2 Current Sources The AS3668 features four general purpose current sources. All current sources and be controlled independently from each other and share internally the same power supply VCP. Table 7. Reg Control Register 0x00 Reg Control register Bit Bit Name Default Access Bit Description 2 cp_on 0 R/W This bit enables the charge pump for operation if at lease one current source is enabled and the current source has a low voltage condition. Once the charge pump is running it will be keep on even if all current sources are switched off. 0: Chargepump off 1: Charge Pump on Table 8. CP Control Register 0x23 Current Control Register Bit Bit Name Default Access Bit Description 6 cp_auto_on 1 R/W This bit enables the charge pump for operation. Once at last one current source is enabled and minimum one current source has a low voltage condition the charge pump is switched on. If all current sources are switched off again the charge will also switch of automatically. 0: Chargepump off 1: Chargepump on in automatic mode 5 cp_start_debounce 0 R/W Selects the startup debounce time of the charge pump 0: 32ms debounce time. 1: 240μs debounce time 4 cp_mode_switching 0 R/W Allows the user to select between automatic mode switching or manual mode switching of the charge pump. If the bit is set, the user can change register cp_mode in order to select 1:1 mode or 1:2 mode of the charge pump. 0: Automatic CP Mode Switching 1: Manual CP Mode Switching using register cp_mode 2 cp_mode 0 R/W Selects the charge pump operating mode if register cp_mode_switching is set to 1. Reading the register return the mode in which the charge pump is operating, either 1:1 or 1:2 mode. 0: 1:1 mode 1: 1:2 mode 0 cp_clk 0 R/W Selects the charge pump clock frequency. 0: 1Mhz 1: 500kHz Table 9. Current Sink Function Overview Current Sink Max. Voltage (V) Max. Current (mA) Resolution Software Current Control Hardware On/Off Control (Bits) (mA) CURR1 5.5 25.5 8 0.1 Separate for each current source Internal PWM; external PWM at GPIO/AUDIO_IN, Pattern generator CURR2 CURR3 CURR4 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |