135 / 158 page ![]() www.austriamicrosystems.com Revision 1v13 134 - 157 AS3658 Data Sheet Confidential - Deta il ed Descri ption - System Functi ons 10.5 Protection Functions All LDO’s, the DCDC step ups and DCDC step downs have an integrated overcurrent protection. An overtemperature protection of the chip is also integrated which can be switched on with the serial interface signal temp_pmc_on (enabled by default; it is not recommended to disable the overtemperture protection). The chip has two signals for the serial interface: ov_temp_110 and ov_temp_140. The flag ov_temp_110 is automatically reset if the overtemperature condition is removed, whereas ov_temp_140 has to be reset by the serial interface with the signal rst_ov_temp_140. If the flag ov_temp_140 is set, an automatic reset of the complete chip is initiated. The flag ov_temp_140 is not affected by this reset cycle allowing the software to detect the reason for this unexpected shutdown. Table 154. Overtemperature Detection Symbol Parameter Min Typ Max Unit Note Table 155. Overtermperature detection Bit definition Addr:106 Overtemperature Control These bits control the startup and are set by factory test Bit Bit Name Default Access Description 10.5.1 Temperature Supervision A temperature sensor is implemented to provide over-temperature protection of the chip. It generates two flags linked to the two temperature thresholds (110 degrees, 140 degrees). Both thresholds have an hysteresis to prevent oscillation effects. First threshold (110 degrees) sets the flag ov_temp_110, signalling the serial interface part and software the 110 degrees overtemperature condition. If enabled (ovtmp_int_mask=0), an interrupt can be send (interrupt ‘ovtmp’). Thus software can react and can shutdown power consuming functions to decrease temperature. The second threshold (140 degrees) initiates a reset cycle and sets ov_temp_140: this sets all regulators into power- down mode and stops charging, and performs the reset cycle of the AS3658. rst_ov_temp_140 flag In case of overtemperature and an activated reset (temp_pmc_on=1), the system loses any information about the error which activated the reset state. Therefore, a flag is implemented, which indicates that the reset was caused by overtemperature activation (ov_temp_140 is set). This flag is only resetable by writing ‘1’ to rst_ovtemp_140. T110 ov_temp_110 rising threshold 95 110 125 ºC T140 ov_temp_140 rising threshold 125 140 155 ºC Thyst ov_temp_110 and ov_temp_140 hysteresis 5ºC 0 temp_pmc_on 1 R/W Switch on / off of temperature supervision; default: on – all other bits are only valid if set to ‘1’ Leave at 1, do not disable 1 ov_temp_110 NA R Flag that the overtemperature threshold 1 (T110) has been reached 2 ov_temp_140 NA R Flag that the overtemperature threshold 2 (T140) has been reached – this flag is not reset by a overtemperature caused reset and has to be reset by rst_ov_temp_140 3 rst_ov_temp_140 0 W If the overtemperature threshold 2 has been reached, the flag ov_temp_140 is set and a reset cycle is started. ov_temp_140 should be reset by writing 1 and afterward 0 to rst_ov_temp_140 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |