7 / 17 page ![]() 7 Regulatory Information Insulation and Safety Related Specifications Parameter Symbol Value Units Conditions Minimum External Air Gap L(I01) 4.9 mm Measured from input terminals to output (Clearance) terminals, shortest distance through air Minimum Externa l Tracking L(I02) 4.5 mm Measured from input terminals to output (Creepage) terminals, shortest distance path through body Minimum Internal Plastic Gap 0.08 mm Insulation thickness between emitter and (Internal Clearance) detector; also known as distance through insulation Tracking Resistance CTI 175 Volts DIN IEC 112/VDE0303 Part 1 (Comparative Tracking Index) Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Reflow Soldering Profile The recommended reflow soldering conditions are per JEDEC Standard J-STD-020 (latest revision). Non-halide flux should be used. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option x6xx) Description Symbol Characteristic Unit Installation classification per DIN VDE 0110, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms I – IV I – III Climatic Classification 40/100/21 Pollution Degree (DIN VDE 0110/39) 2 Maximum Working Insulation Voltage V IORM 567 V peak Input to Output Test Voltage, Method b* V IORM x 1.875 = VPR, 100% Production Test with t m=1 sec, Partial discharge < 5 pC V PR 1063 V peak Input to Output Test Voltage, Method a* V IORM x 1.6 = VPR, Type and Sample Test, t m=10 sec, Partial discharge < 5 pC V PR 907 V peak Highest Allowable Overvoltage (Transient Overvoltage t ini = 60 sec) V IOTM 4000 V peak Safety-limiting values – maximum values allowed in the event of a failure. Case Temperature Input Current** Output Power** T S I S, INPUT P S, OUTPUT 175 150 600 °C mA mW Insulation Resistance at T S, VIO = 500 V R S >109 W * Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles. ** Refer to following figure for dependence of PS and IS on ambient temperature. Ts-Case Temperature,°C 700 600 500 400 300 200 100 0 0 200 50 25 75 100 125 150 175 Is (mA) Ps (mW) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |