31 / 76 page ![]() AN4266 Functional safety requirements for application software Doc ID 024283 Rev 2 31/76 Mandatory: The output write of a redundant PWM channel must be implemented by writing the new output values to both the PWM channels. The customer can decide whether to use both eTimers (eTimer_0, eTimer_1) or both FlexPWMs (FlexPWM_0, FlexPWM_1), See Figure 6. Note: Rationale: To write a digital output by exploiting redundancy, and modules must belong to different lakes to decrease the probability of CCF Implementation details The following hardware elements shall be used for the safety function: ● eTimer_0 channels ● eTimer_1 channels ● FlexPWM_0 channels ● FlexPWM_1 channels Mandatory: The pads shall be configured via the appropriate pad configuration registers (PCRn) in the SIUL module. Note: Rationale: To configure pads used by this safety function Single Write PWM Outputs With Read Back The hardware elements eTimer_0 and FlexPWM_1 or eTimer_1 and FlexPWM_0 are used to perform a Write PWM Output With Read Back(f). These units must be configured to implement one PWM output channel and (via internal read back) the eTimer_0 input PWM channel. The SIUL must be configured to define the configuration of the output pads used. The software must perform a write operation followed by a read operation. To guarantee the integrity of the two output channels, the application should test the SIUL configuration implementing the SIUL_SWTEST_REGCRC (to avoid a common failure caused by misconfiguration of the pads). Table 8. Software BIST and/or test Software BIST or test Frequency SIUL_SWTEST_REGCRC Once after programming(1) 1. If a change in a single SIUL configuration register is capable of affecting both the output and the read-back paths, then SIUL_SWTEST_REGCRC must be executed every FTTI. In all other cases configuration errors are covered by the software comparison. ETIMER0_SWTEST_REGCRC(2) 2. This software BIST is needed only if the FlexPWM channels are used for the safety function Once after programming ETIMER1_SWTEST_REGCRC(2) Once after programming FLEXPWM0_SWTEST_REGCRC(3) 3. This software BIST is needed only if the eTimer channels are used for the safety function Once after programming FLEXPWM1_SWTEST_REGCRC(3) Once after programming PWMDW_SWAPP_WRITE Once every write f. eTimer_0 and FlexPWM_0 (eTimer_1 and FlexPWM_1) cannot be used in combination due to the same LBIST partition assignment. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |