11 / 40 page ![]() UM0272 System parameters 11/40 2 System parameters 2.1 Introduction System parameters can be configured by using either the Control Module or the PC Interface. Using the PC interface provides the advantage of using a user-friendly graphic interface (GUI) to configure the system parameters off-line. Once the system is configured on its own PC, it is possible to download information to the CU. For safety reasons and in order to avoid any tampering from a different installer, a system installation code is required before entering Parameter Setting mode on the CU. 2.2 Zones Each zone is balanced, meaning that the CU detects any resistance variations on the input line. A certain resistance value is assigned during the installation and when an imbalance is detected, it is considered as an infraction and processed. In each zone, a resistor can be placed between each zone terminal (i.e. J20 to J24 for the hard-wired zones). In this case, the value of each resistor can be decided by the installer and it is not necessary to set the same value for each zone. Using this feature ensures that any additional resistance values coming from the wiring do not affect system performance. Each zone can be included or excluded from the control flow (i.e. if a sensor is broken the zone in which it is connected can be temporary excluded), and the working mode can be set either as normally closed (NC or balanced) or normally opened (NO or unbalanced). The zone status variation is immediately stored by the CU when detected, but it is processed only once the delay time associated to the zone is elapsed (if any delay is set). Each zone can be logically associated to all the others in OR (as default) or in AND modes. In AND mode, status variations are detected and processed by the CU only if all the zones in AND mode have their status changed too. Each zone can be in AND mode with another zone, but the vice versa is not mandatory. For example, Zone 4 can be in AND mode with Zone 5 (Zone 4 is now seen as Group 4), but Zone 5 is not in AND mode with Zone 4 (Zone 5 is associated to Zone 4 in OR mode). Each zone is protected against negative voltage, over voltage and ESD. 2.3 Outputs Each output behavior can be configured as “change status” (ON for a certain time followed by an OFF period or vice versa) or “toggle status” (each time an alarm condition occurs, the output status is toggled). One or more outputs can be associated to each zone and can be enabled or disabled from the system. The default level of each output can be configured as high or low. Four outputs are SSR outputs that can supply up to 1A (internally limited) depending on the power supply capacity (connectors J25/J26, J27/J28, J29 and J30). Typically such outputs are dedicated to sirens (self-powered and internal) and for other devices that require power (connectors AUX1 and AUX2). Two outputs (J32) are transistorized general purpose outputs that can be configured for signaling alarm conditions or the CU status. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |