| Electronic Components Datasheet Search |
|
UM0934 Datasheet(PDF) 83 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
UM0934 Datasheet(HTML) 83 Page - STMicroelectronics |
|
83 / 113 page ![]() UM0934 Management information base (MIB) Doc ID 17389 Rev 2 83/113 6.5.26 0084h (transmitted alarm counter) This object counts the number of the transmitted alarms, even if repeated. The confirm message of a CMD_ReadDBRequest returns the current value of the counter without changing it. The CMD_WriteDBRequest resets the value of the counter (0) and the confirm message returns the reset value (0). Table 128. MIB object 0084h: Write request data format Byte Label Description Available range Factory default 0..3 Transmitted alarm counter PAD word (any value) 0 .. FFFFFFFFh 0 Table 129. MIB object 0084h: Read/write confirm data format Byte Label Description Available range Factory default 0..3 Transmitted alarm counter Transmitted alarm counter value 0 .. FFFFFFFFh 0 Table 130. MIB object 0084h: Write error data format Byte Returned value Error description 0 ERR_ILLEGAL_DATA_COMMAND Wrong number of data bytes |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|